Product specifications
Installing the VoIP Clock Kit Wall Mount Adapter
Verifying Operation of the Clock Kit Adapter
Operations Guide 930283F CyberData Corporation
12
2.2 Verifying Operation of the Clock Kit Adapter
2.2.1 Identifying the VoIP Clock Kit Jumpers
See Figure 2-11 and Table 2-1 to identify the jumper locations and functions.
Figure 2-11. Jumper Locations
Note Prior to installing the Clock Kit, make sure that JP1 is installed. This powers the Real Time
Clock from the battery. If you do not, the clock will loose it's time when the power is
disconnected.
JP1 JP2JP3 JP4 JP5
Table 2-1. Jumper Functions
Jumper Function
JP1 Battery - Connect
JP2 Manufacturing - Open
JP3 Manufacturing - Open
JP4 Manufacturing - Open
JP5 Manufacturing - Open