LED Keypad User Manual
PUBLICATION INFORMATION 7051 R First Publication EliteSuite™ LED Keypad User Manual
CONTENTS INTRODUCTION ...................................................... 1 OPERATION ............................................................ 2 USER CODES ........................................................... 5 SETUP LOGIN.......................................................... 6 USER SETUP OPTIONS ............................................ 7 PROGRAMMING USER CODES ....................................................... 7 MODIFYING USER OPTIONS .............................................
INTRODUCTION Your suite has been equipped with the EliteSuite™ Security System. The EliteSuite™ Security System will give you peace of mind by providing reliable security protection. The EliteSuite™ System is an advanced technology security system specifically designed to enhance the functionality of condominium and apartment security with flexible local monitoring and offsite communication.
OPERATION The following section provides you with information on how to use the EliteSuite™ keypad. When the text [USER CODE] is shown this indicates that you are required to enter your user code. The default Master Code to gain access to your system is . This code MUST be changed, see page 5 for how to program user codes. Many of the features and options must be enabled by the installation company or property manager.
Power / Trouble Indicator FLASHING: There is a trouble condition present. Contact your building manager or security company for assistance. ON: the system is powered and operating normally. OFF: Complete power failure. Contact your building manager or security company for assistance. Ready Indicator ON: The system has all zones closed and is ready to be armed. OFF: One or more zones in the system are open and the system cannot be regular armed.
VISUAL DISPLAY The EliteSuite™ LED keypad features an easy to use 8 zone display, which in conjuction with the status LED’s allows you to monitor your system at a glance. When not using the menu system for programming options or modifying user accounts, your keypad will display the status of each programmed zone by lighting the corresponding number on the display. The 3 status options shown are: FLASHING CONTINUALLY: The zone is operating incorrectly.
USER CODES User Codes are personal identification numbers that allow you to enter certain programming modes, arm or disarm your EliteSuite™ system as well as activate or deactivate home automation functions. The EliteSuite™ system supports up to eight user codes. MASTER CODE By default User 01 has the master code for your system. A master code can perform the arm or disarm functions and modify and delete any user code, change user options and modify user card numbers.
SETUP LOGIN Logging Into the Setup Menu Enter the following keypress sequence to access the setup menu: MENU ( ) , [USER CODE] Example: For the default master user to log in to the setup menu, the sequence is: , , , , The ARMED status LED will begin to flash once you have successfully logged in, informing you that you are in programming mode.
USER SETUP OPTIONS PROGRAMMING USER CODES Your EliteSuite™ system uses four digit user codes, where each digit can be any value from 0 to 9. Avoid programming simple or obvious user codes, such as part of your telephone number or address and codes such as 1234, 1111 or 1212. Entering New User Codes or Changing Existing Codes Each user’s code can be modified with the following sequence, in which the new user code must be entered twice to confirm the new code has been entered as intended.
• If correct, the confirmation tone will sound and the ARMED LED will return to a slow flash. • If incorrect, a rejection tone will sound and the confirmation process must be repeated.
MODIFYING USER OPTIONS The User Option menu contains options for arming, disarming and door latching for the optional Card Reader interface. If your EliteSuite™ system is not equipped with a Card Reader interface, changes to these options will have no effect.
6 Disabled allows the user code to arm and disarm the EliteSuite™ system. • Option 2 – Master User 5 Enabled allows the selected user to access the User Setup menu and modify codes, card numbers and options of all other users. 6 Disabled prevents access to the User Setup menu. • Option 3 – Single Badge Disarming For Card Reader Interface Equipped Systems Only 5 Enabled allows the selected user to disarm the EliteSuite™ system by presenting the card programmed for that user at the Card Reader.
• Option 4 – Triple Badge Arming For Card Reader Interface Equipped Systems Only 5 Enabled allows the selected user to regular arm the EliteSuite™ system by presenting the card programmed for that user at the Card Reader three times in quick succession. 6 Disabled prevents triple card presenting from arming the system.
• Option 7 – Triple Badge Latch 4 Hours For Card Reader Interface Equipped Systems Only 5 Enabled allows the selected user to hold a door open for 4 hours upon presenting their card 3 times in quick succession. 6 Disabled prevents triple card presenting from latching the door open. • Option 8 – Triple Badge Latch 8 Hours For Card Reader Interface Equipped Systems Only 5 Enabled allows the selected user to hold a door open for 8 hours upon presenting their card 3 times in quick succession.
USER CARD NUMBERS This menu is only for Card Reader interface enabled Keypads. The EliteSuite™ Alarm system is able to be interfaced with a EliteSuite™ Card Reader device to provide proximity card access to your condominium. If the Card Reader interface has been installed, each user can be assigned a unique card number that is stored on a proximity device.
TROUBLE CONDITIONS The EliteSuite™ Security System continually monitors five system trouble conditions that can occur on your system. When a trouble condition occurs the EliteSuite™ keypad can be programmed to generate an audible tone every 120 seconds. The trouble tone is cancelled when the trouble condition is viewed or the condition is returned to normal.
TROUBLE LIST The troubles that can occur in your system are detailed in the following list. TROUBLE #8 - Host Comms Communication with the host system is currently offline. This is possibly due to maintenance or a system fault. Contact the property manager or security installation company if the problem persists. TROUBLE #7 - Zone Fault A zone in the system is faulty or the wiring has been damaged. Contact the property manager or security installation company to arrange for your system to be serviced.
ARMING/DISARMING To take full advantage of your EliteSuite™ System, you should familiarize yourself with the different arming methods. EXIT DELAY After entering a valid arming sequence the exit delay time will provide you with enough time to exit the protected area before the system arms. The keypad will generate a beepbeep tone repeatedly during the exit delay period. The tone will increase in frequency to indicate that only ten seconds remains.
2. Enter your [USER CODE]. REGULAR ARMING Regular arming arms your system. Arming Your System 1. Check that the system is ready to arm and all zones are closed (Ready Indicator is Green). 2. Enter your [USER CODE]. 3. The exit delay beep will start and you can now leave your premises. Quick arming can be used by pressing and holding the arm key. This option MUST be enabled by your property manager or installation company. See the configuration section on page 25.
Instant Arming Your System 1. During the EXIT DELAY press and hold the key for 2 seconds. The system will instant arm all zones, any zone will trigger the alarm immediately. Fast Stay Arming 1. To fast stay arm your system press and hold the stay key for two seconds. Switching From Stay To Regular/Force Armed 1. If you need to leave your premises and want to arm the system fully you can use the fast exit arming method.
To fast force arm your system press and hold the force key for two seconds. This option MUST be enabled by your property manager or installation company. Refer to the system configuration table on page 25. BYPASSING ZONES Bypassing zones allows you to program the alarm system to ignore (deactivate) specified zones the next time the system is armed. For example, you may wish to bypass certain zones when workers are renovating part of your establishment.
1. Press the bypass key then enter your [USER CODE]. 2. Press and hold the bypass key for 2 seconds the last settings will be loaded. You may change these settings if required. 3. Press the enter key to store the bypass settings and exit. 4. Press the clear key to exit without making changes. ONE KEY ARMING One key arming can be used to arm the system in regular, force, stay and instant arming modes. You can use this feature to allow specific individuals like service personnel (i.e.
SPECIAL FEATURES The EliteSuite™ System offers many unique features. ALARM MEMORY All zones that generate an alarm will be stored in the memory of the EliteSuite™ Keypad. If an alarm has occurred on your system, the alarm memory status LED will be lit until the the next time you arm your system. Viewing Alarm Memory 1. Press and hold the memory key for 2 seconds or press memory and enter your [USER CODE]. 2. The LED’s corresponding to the zone(s) which generated the alarm will be lit. 3.
CHIME ZONES A chime enabled zone will generate an audible tone every time that the zone opens, ideal for a front door. Chiming Zones To enter Chime Zone select mode, log in to the Setup menu and press: , you can now toggle chime mode on any zone by pressing the number corresponding to the required zone. The zone LED will be lit for each chimed zone. Press the enter key to store the chime settings and exit., or press the clear key to exit without making changes.
MESSAGES The EliteSuite™ system message handling capabilities to allow communication with a property manager. A new message that has been sent to your system is announced by an audible tone and the MESSAGE LED being lit. Clearing Messages To clear the Message LED, log in to the Setup menu and press: , , To choose another menu option press the menu to exit press the clear key.
FIRE ALARM When a fire alarm occurs, the EliteSuite™ will emit three audible tones at 2 second intervals until reset by entering a valid user code. If the zone is a delay fire zone, there is a delay of thirty seconds before the system contacts the security company or property manager. A delayed fire zone will prevent unnecessary reporting of false alarms allowing you to reset the fire alarm before a report is sent.
CONFIGURATION The EliteSuite™ system has many options that are enabled by your installer. The following lists the options and how your system is configured. Use this location to write your user names and any information about your system. ZONE DESCRIPTION The following lists the zones in your system and how each zone is configured. ZONE 01 02 03 04 ZONE NAME ZONE 1 ZONE 2 FORCE STAY BYPASS 5 5 5 5 5 5 FIRE ZONE The following lists the fire zone configuration for your system.
ONE KEY ARMING The following lists the one key arming method(s) that are enabled on your system. Enabled Disabled Regular Arming 5 Stay Arming 5 Force Arming 5 Instant Arming 5 PANIC KEYS The following lists the panic key configurations that are enabled on your system.
TIMERS Your entry time is programmed to be _030_ seconds. This is the time that you have before an alarm is generated if you enter through the zone __ZONE 1__. Your exit time is programmed to be _030_ seconds. This is the time that you have to exit before the system arms. If an alarm occurs the siren/beeper will activate for _005_ minutes unless disarmed. USERS The following table should be used to keep a record of the users programmed in your EliteSuite™ system. Record the name of the user only.
WARRANTY The Seller warrants its products to be free from defects in materials and workmanship under normal use for a period of one year. Except as specifically stated herein, all express or implied warranties whatsoever, statutory or otherwise, including without limitation, any implied warranty of merchantability and fitness for a particular purpose, are expressly excluded.
Unit C, 6 Ascension Place, Mairangi Bay, P.O. Box 302-340 North Harbour, Auckland, New Zealand. Phone: +64 (9) 476 7124 y Fax: +64 (9) 476 7128 www.integratedcontroltechnology.