Installation Guide

63 | C y b e r - R a i n X C I S m a r t I r r i g a t i o n C o n t r o l l e r U s e r G u i d e
o Your threshold for over current alerts is set too low. Adjust the Over Current Threshold in the Current Sensor Alert Settings panel on the
Controller page.
How to clear alert and resume watering for the affected zone:
o This alert will automatically clear itself when the current going through the valve returns to normal levels.
o Manually run the zone from either the controller or computer after the underlying cause has been addressed.
o Manually clear the alert by pressing Clear Alerts under the stoplight in the Controller Status panel on the Controller page. (Note: The alert will
return the next time Cyber-Rain waters this zone if the current remains above the maximum threshold.)
Under Current Alert
Indicates: Current going through a valve is below the minimum threshold when that zone is running.
Cyber-Rain response: Alert is triggered, but the controller continues to water all zones.
Potential causes of alert:
o A sprinkler valve is failing and not opening sufficiently.
o The sprinkler valve wire is not properly inserted in the valve harness.
o Your threshold for under current alerts is set too high. Adjust the Under Current Threshold in the Current Sensor Alert Settings panel on the
Controller page.
How to clear alert:
o This alert will automatically clear itself when the current going through the valve returns to normal levels.
o Manually run the zone from either the controller or computer after the underlying cause has been addressed.
o Manually clear the alert by pressing Clear Alerts under the stoplight in the Controller Status panel on the Controller page.(Note: The alert will
return the next time Cyber-Rain waters if the current remains below the minimum threshold.)
Flow Alerts
Flow Alerts indicate when abnormally high or low water flow is detected. An optional flow meter must be properly installed to detect flow alerts and the normal
flow must be set for each valve. See Installing and Using a Flow Sensor in this User Manual for more information on proper set up. Potential flow alerts are:
Flow Hold Alert
Indicates: Water is flowing through the valves when all sprinklers are off.
Cyber-Rain response: Alert triggered and THE CONTROLLER WILL NOT WATER ANY ZONES until the alert is cleared.
Potential causes of alert:
o A sprinkler valve has malfunctioned and is stuck open.
o Your main line has a leak.
How to clear alert and resume watering:
o This alert will automatically clear itself when no water flow is detected for one minute.
o Manually clear the alert by pressing Clear Alerts under the stoplight in the Controller Status panel on the Controller page. (Note: The alert will
return if the flow continues when all of the sprinklers are off.)