4. Current Sensor Alert Settings (Pro Model Only): Cyber-Rain automatically measures the electrical current flowing through each valve while it is in use,
and will alert the user of abnormally high or low measurements. Current alerts can be helpful in determining if a valve wire hasn’t been inserted properly
or is failing. The default settings for over/under current alerts are set to a wide range to avoid unwanted alerts.
To activate low current alerts, set an under current threshold above 0 and safely below the typical current levels of your valves. The existing current
levels can be read by manually running a zone and watching the current gauge on the Schedule page. An under current threshold of 150 milliamps is
generally appropriate for most residential settings. The default over current alert threshold is 750 milliamps, which should be suitable for most
installations. Cyber-Rain will stop watering the zone when a high current alert has been tripped, so the threshold should be set with care. See
Controller Alerts section for more details.
5. Rain Sensor Settings: If a compatible rain sensor is installed, make sure the Rain Sensor Installed box is checked.