Specifications

Device Failure
Code and Error
55
Status
56
Mass memory
buffer expired
57
Buffer
transfer
58
Not used
59
PE
lost
data
60
megaltape
motion request
61
Interrupt
status
bit
62
ADT
63
Busy
after
EOP
64
Not busy
65
No
interrupt
selected
66
Memory
address
67
Not used
68
Interrupt
status
bit
69
Initialization
not enabled
70
Connect
6-6
Significance
Bad
status
(an indeterminate error
occurred on 1752)
No
more buffer space is available
(software buffer driver).
A mass memory error
on
the buffer
transfer, which is detected
in
the
software buffer driver.
An
error occurred
in
the phase en-
code formatter
that
affected
the
data
transfer.
An
illegal tape motion request was
made
to
the magnetic tape simulator.
1833-5 Flexible Disk: The interrupt
should not be
set
when the initial
status
is taken.
1829-30/60 Card Reader:
no
inter-
rupt
status
indication
1833-5 Flexible Disk: same
1829-30/60 Card Reader: B.uto-data
transfer fault status
1829-30/60 Card Reader:
still
busy
after
end-of-operation occurs
1829-30/60 Card Reader: not busy
before end-of-operation occurs
1833-5/1865-1 Flexible Disk:
no
interrupt select
status
bit when the
interrupt occurred
1833-5/1865-1 Flexible Disk: The
direct memory access memory
address fault or A/Q transfer
attemp-
ted
to
cross a bank boundary or the
direct memory access
attempted
to
cross a bank
boun~ary
without
priming the request (motion request
of code
= 1).
1833-5/1865-1 Flexible Disk: The
interrupt status bit was not
set
when
the interrupt occurred.
1833-5/1865-1 Flexible Disk: The
disk initialization switch was not
set.
1833-1 Disk: failure
to
connect to
the control unit or drive
after
a
maximum number of retries.
Device Failure
Code and Error
71
ECC
72
Ghost interrupt
73
Force release
74
Transfer length
75
Transfer
76
Recovery
indicator
77
Expected
reject
did not occur
78
Transfer
79
Unit busy
80
Unit seeking
81
Unit doing
input/output
82
CU
83
Main
memory
Significance
1833-1 Disk: The error correction
code could not
correct
the error,
since too many error bits were gener-
ated.
1833-1 Disk:
An
unexpected
inter-
rupt was received.
1833-1 Disk: A force release was
required but the disk was not released
(multiple disk adapter system).
1833-1 Disk: The
data
transfer was
longer than requested.
1833-1 Disk: The data transfer was
not accomplished
after
the maximum
number of retries.
1833-5/1865-1 Flexible Disk:
An
in-
formative error was logged
in
the
engineering file
to
indicate recovery
has been performed
on
this device a
specific number of times. The
threshold value for the error is con-
tained
in
word
43
of the physical
device table for this unit.
1833-5/1865-1 Flexible Disk (diag-
nostic logic unit only):
An
illegal
function was issued but did not cause
a reject.
1833-5/1865-1 Flexible Disk: The
number of words transferred was not
correct
or the spindle speed during
initialization of the disk was more
than 3.5 percent
off
the
normal
value.
1833-5/1865-1 Flexible Disk: The
unit is busy
at
the
time
the
input/out-
put request is
attempted.
1833-5/1865-1 Flexible Disk: The
unit is seeking when
the
input/output
request is attempted.
1833-5/1865-1 Flexible Disk: The
unit is doing input/output when the
input/output request is
attempted.
1833-1 Disk: error
in
1833-3 Control
Unit
1833-1 Disk: The disk adapter
attempted
to
address a nonexistent
central processing unit memory
address.
96769450 A