Specifications
INPUT/OUTPUT
STATEMENTS
6
Three types
of
input/output equipment diagnostics
are
provided.
• The basic failure message
(LV
xx FAILED
yy)
that
specifies the unit (xx)
that
failed and the code (yy)
that
specifies
the
failure cause
•
Other
failure messages produced
by
a few controllers
(special messages)
•
Status
information.
In
this manual, only those
status
words
are
described
that
are
readily available
to
the
user; i.e., the engineering log
status
(PHYSTB, word 12)
and
other
status
words saved
in
PHYSTB.
The
first
and second types of diagnostics
are
produced for
all input/output devices. For additional information
on
the
status
words, the hardware maintenance manual for the
individual device should be consulted.
BASIC
EQUIPMENT
MALFUNCTION
When
a system input/output device driver has
detected
an
error,
the
alternate
device handler is called. The
alternate
device handler prints the following diagnostic message
on
the standard comment device
if
no
alternate
device is
defined:
LV,nn FAILED
xx
ACTION
Where:
nn
is
the
number of
the
logical unit
that
failed
xx
is the failure code.
Respond
to
the
error
by
typing one
of
the
following:
RP To
repeat
the request
CU
CD
DU
DD
To
report
the
error
to
the requesting program; the
device is allowed to continue processing requests.
To
cause any future programs calling the device
to
be informed of the failure
by
their completion
addresses. The
error
is reported
to
the calling
program and the device is marked down.
No
subsequent
attempt
is made
to
operate
this device.
To
activate
control unit and suspend job processing.
If job processing is not
in
progress, this action is
not taken and
ACTION
is retyped. Another option
may be selected.
To
activate
control unit and suspend job processing.
If job processing is not
in
progress, this action is
not taken and ACTION is retyped. Another option
may be selected.
96769450 B
DEVICE FAILURE CODES
Device Failure
Code and Error
o Time-out
1 Lost
data
2 Alarm
Significance/ Action
I
Failure
to
interrupt
within the
allot-
ted
time (requires
TIMER
package)
. Teletype: The
operator
failed to
supply input within the
allotted
time.
Ignore the message and continue nor-
mally.
All
other
devices: The hardware
failed
to
generate
an interrupt within
the allotted time. Hardware main-
tenance is required.
Data was not
transferred
out of the
read
register
before the next
data
word appeared.
1711/1713 Teletypewriter: Retype
the
statement.
1829-30/60 Card Reader (diagnostic
logic unit only): bad initiator
status
1833-5 Flexible Disk: bad initiator
pseudo
status
Magnetic tape: Use the control unit
option
to
continue without processing
the lost record or
abort
the read
option.
Indicates the presence of an abnormal
condition
1713 Paper Tape Reader: paper
tape
motion failure.
No
change
in
the
feed hold circuit has occurred for
40
milliseconds while trying
to
read.
If
not the end-of-tape, manually posi-
tion the paper
tape
so
that
the end
of
the
next
to
last
record and the
beginning of the
last
record
are
on
opposite sides
of
the photocells.
If
end-of-tape,
take
the control unit
option.
Paper
tape
punch: paper
tape
supply
low or
tape
break. Abort the punch
operation and
correct
the problem.
6-1