Specifications
Message
13
14
15
16
17
18
19
20
21
22
23
96769450 A
Significance/COSY Action
DEL/ or
INS/ card contains sequence
number beyond the end
of
the input deck.
Action: Reads revisions and lists them
with asterisks in columns 1 through 4 until
it
reads a DCK/, MRG/, or END/ card.
illegal parameter
on
DCK/ card
Action: Reads revisions and lists them
with asterisks in columns 1 through 4 until
it
reads a DCK/, MRG/, or END/ card.
Parameter
on
DCK/ card twice.
Action:
Uses a second parameter.
DCK/ card requests both H and C or H
and L on the same unit.
Action: C or L parameter is ignored;
processing continues.
DCK/ card requests input from logical
unit previously used for output.
Action: Reads revisions and lists them
with asterisks in columns 1 through 4 until
it
reads a DCK/, MRG/, or END/ card.
COSY
output is requested
on
unit pre-
viously used for Hollerith output or
Hollerith output is requested
on
unit
previously used for
COSY.
Action: illegal output
requestJs
__
cleared;
processing continues.
Maximum number of output units is
exceeded.
Action: Output is cleared; processing
continues.
The DCK/ card requests output
on
a
logical unit previously used as input.
Action: The output is removed; process-
ing continues.
The DCK/ card requests C and L output
on
the same unit.
Action: The L parameter is
ignored-
processing continues. '
The
CPY
/ control card is not the first
card of the revisions deck.
Action: The
CPY
/ control card is listed
with asterisks
in
the first four columns
and the next control card is read.
The
CPY / card
was
not followed
by
a
CPY
/ or END/ card.
COSY
aborts.
Message
Significance/COSY Action
L,lu
FAILED
ec
COSY
driver errors
are
output by the
alternate
device handler. All errors
are
catastrophic.
Action: For protected requests, type
CU.
For unprotected requests, type
DU.
ec = 1 Not assigned.
2 First record read was not a
CSY
/
record.
3 END/ card was not the
last
card
on
COSY
input.
4
No
end-of-file
on
COSY
input.
5 A read request was made
to
a
logical unit assigned
to
output,
or a write request was made to a
logical unit assigned
to
input.
6 A motion request was made
to
a
logical unit assigned
to
input!
output, and
no
end-of-deck
marker was encountered.
REWIND
LUnn
This message may appear
at
various times
during a
COSY
job. The specified number
is the decimal logical unit to be rewound.
Action: The operator must
enter
any
value through the standard input comment
device
after
rewinding the unit.
SORTING
AND
LISTING
Four utilities are included in this group:
EESORT
processes relocatable binary programs
to
prepare a
listing of program name, card comments, length, common
size, data size, entries, and externals. There is only one
diagnostic message:
Message
Significance
MEMORY
OVERFLOW
-
NO
SORT Not enough core to
process the program
OPSORT
operates
on
1700
series assembly language oper-
ands. There are
no
diagnostic messages.
L~STR
lists the name and record length of all programs on a
bmary tape. There
are
no
diagnostic messages.
LULIST
lists the system logical units.
diagnostic messages.
PROGRAM
TRACE
There
are
no
Trace provides the operator with the ability to list certain
information about a running program. The program cannot
trace
through protected core (e.g., monitor calls, jumps to
5-5