Specifications
Message
The
messages
are:
Significance
CHKWRD ERR Check on read
GUARDED ADDRESS
Attempt
to
write
on
protected
ERROR
track
LOST
DATA
NOT READY
POWER
FAILURE
PROTECT
FAULT
SECTOR OVER-
RANGE ERROR
TIMING
TRACK
ERROR
Events counter (1547)
Data
not
taken
off
of,
or
sent
to,
DSA
within
acceptable
time
Power
not
on,
speed
low,
or
temperature
or
pressure
out
of
tolerance
Lost ac power
to
drum
Tried
to
access protected core
Attempted
to
access nonexistent
track
Lost
drum
timing
pulses
DASH NO. ERROR Choices are 1 and 2
INTERR UPT
Interrupt
on
wrong
line
ASSIGNMENT
ERROR
NO INTERRUPT
Interrupt
selected
but
not
gener-
ated
OUTPUT TYPE
ERROR
1572-1 SYN. NOT
SYSTEM
TIMER
Hardware
error
messages
have the
following preamble:
TSTCTR
TEST
xx
RUN yyyy
The
messages
are:
COUNT ERR
NO READ CLEAR
READ
CLEAR
STATUS ERR
Followed by:
ACTUAL
aaaa
EXPECTED bbbb
CTRWEMS cccc
TSTCTR TEST
xx
RUN
yyyy
CTRWEMS
aaaa
INT
REJECT
EXT
REJECT
A=cec
X=dddd
96169450
A
Required
for
testing counting,
interrupts, and events/unit
time.
xx
is
test
1
or
2;
yyyy
is
run
number
Where the
actual
and expected
values are given
for
the event
counter
with
WES
code cccc
Reject
message giving Q,
A,
and
X register values
Q = bbbb
Message
Significance
Line
printer
(1740/501.
1742-1,
1742-30.
1742-120)
Hardware
error
messages
have the
following preamble:
TSTPRT SECTION
xx
Where section number
is
one
of
the six tests
in
bit
configuration
The
messages
are:
ALARM
EXT REJ
INT
REJ
TIME
OUT
Followed by:
(2,4,8,1°16,2°16,4°16)
Out
of
paper,
torn
paper,
inter-
lock
open,
or
fuse alarm
Printer
busy
or
not
ready
Device did
not
reply
to
CPU
in
allotted
time
Device did
not
generate
inter-
rupt
in
allotted
time
CNTRL NOT READY Indicates
controller
status
or
CNTRL READY
Magnetic tape
(1731/601,
1732-2/615-73,
and 615-93,
1732/608
and
/609,
1732/608 and
/609,
1706,
1732-3/-
616-72, 616-92, and 616-95)
TSTMTT
SEC
xx
RUN yy TAPE
UNIT
zz COMP ERR
RECORD aaaa
WORD
bbbb
WAS
cccc IS
dddd
Hardware
error
messages
have the
following preamble:
TSTMTT
SEC
xx
RUN
yy
TAPE
UNIT
zz
The
messages
are:
Data
error
on specified run and
unit.
Expected and
actual
words
received are shown. Tests (sec-
tions) are
2, 4, 8, and 10
16
•
CORRECTED On reread
DROPOUT (615 only)
END
OF
TAPE
ILLEGAL
DENSITY
SELECTED
(615. 616)
LOST
DATA
NO
ID
(615, 616)
NO
WRITE RING
556 and 800
bits
per inch are
legal
on seven-track 800, and
1600
bits
per inch are legal
on
nine-track.
More data
to
register before
data
transferred
Drive
not
properly addressed
Write
command,
but
tape lacks
write
ring
4-13