DIAGNOSTIC MESSAGES
Message Meaning Action Required
_ _ Temperature Unknown After the pump has been
running for 2 minutes, the
temperature will be displayed.
HH “Overheat” – The spa DO NOT ENTER THE WATER.
has shut down. Remove the cover and allow water
One of the sensors has to cool. Reset by pushing any button.
detected 118°F/48°C
at the heater.
OH “Overheat” – The spa DO NOT ENTER THE WATER.
has shut down. One of Remove the spa cover and allow
the sensors has detected the water to cool. At 107°F/42°C
that the spa water is the spa should automatically reset.
110°F/43°C. If it does not, shut off the power to
the spa and call Cyanna Valley or
your service organization.
IC “Ice” – Potential freeze No action required. The pump(s)
condition detected. will automatically activate
regardless of spa status.
SA The spa has shut down. If the problem persists, contact
The sensor that is your dealer or service organ-
plugged into the ization. (May appear temporari-
Sensor “A” jack is not ly in an overheat situation and
working. disappear when the heater cools.)
SB The spa has shut down. If the problem persists, contact
The sensor that is your dealer or service organ-
plugged into the ization. (May appear temporari-
Sensor “B” jack is not ly in an overheat situation and
working. disappear when the heater cools.)