Installation Instructions
Contractors Wardrobe
®
, 26121 Avenue Hall, Valencia, CA 91355 | Phone: 661.257.1177 Fax: 661.257.4907 | CwDoors.com
Zephyr
™
-PRIN-2830-0620
6
Step 5  Installing the Header
A.   Using the tape measure, measure the distance 
between the top of the left Wall Jamb and the top 
of the right Wall Jamb. (Remember, the width at the 
bottom of the enclosure may NOT be the same as 
the width of the top of the enclosure because walls 
may not be plumb and square).
B.  Locate the Header. Using the miter box and 
hacksaw, cut the Header to the length you just 
measured.
C.  Installing the Soft Close into the Header
1. Remove the four Soft Close mechanisms 
from the box along with the Soft Close plates 
and screws.
2. Attach a SHORT plate to the top of one Soft 
Close nearest the “catch,” with the included 
Screw. Repeat with the other three Soft Close 
mechanisms and plates. Do not over tighten.
3. Fasten one short Screw to the plate with two 
holes. Repeat with the remaining three plates.
4.  Attach a LONGER plate to each Soft 
Close on the end furthest from the “catch”. 
With the included Pan Head Screw, repeat 
with other three Soft Close mechanisms.  
Do not over tighten.
4. Slide two Soft Close mechanisms into one 
end of the top of the Header (See Figure 5a). The 
end of each Soft Close with the “catch” should 
be positioned closest to the end of the Header.
5.  Repeat with the other two Soft Close 
Figure 5a
Soft Close
(#10)
Header
(#1)
Soft Close
catch
Longer 
plate
Short 
plate
Step 4   Installing the 
  Panel Locator/Bumpers
See  Figure 4 to position the Panel Locator/Bumpers. 
Secure with #8 x 1-1/2” PH SMS Screws.
Panel Locator/ 
Bumper (#5)
Left 
Wall Jamb 
(#2L)
Panel Locator/ 
Bumper (#5)
Panel Locator/ 
Bumper (#5)
Panel Locator/
Bumper (#5)
Right 
Wall Jamb
(#2R)
Figure 4
C.  Use a pencil to mark the position of each of the 
three pre-drilled holes in the left Wall Jamb. Set the 
Wall Jamb aside for the moment.
D.  Using either a 1/8” drill bit (for a fiberglass 
enclosure) or a 3/16” masonry drill bit (for tile) drill 
three holes where you made the marks. If installing 
in a tiled enclosure, gently tap a Screw Anchor into 
each hole. DO NOT use the Screw Anchors for a 
fiberglass enclosure.
E.  Place the Wall Jamb back over the Curb and 
against the wall and secure with a single #8 x 1 1/2” 
FH SMS Screw in the MIDDLE hole only.
F. Repeat Steps 3A-D for the right Wall Jamb, 
marked on the bottom with an “R.”