User guide
Troubleshooting
53
Notes 1 Drive Activity - LED may be off for a length of time during power up.
2 Impacted - any background service, e.g. initialization
Figure 4–2 Drive Carrier LEDs
4.4.1 Auto Start Failure
Unless otherwise selected at installation time, all drives in the enclosure should automatically start their
motors after power is applied. If this has not occurred there is a power problem (An alarm and power fault
indication would normally be active).
4.5 Troubleshooting
The following sections describe problems, with possible solutions, which can occur with your FC60SS
Enclosure Platform.
4.5.1 System Faults
Symptom Cause Action
1 The CONTROLLER
FAULT LED will
illuminate AMBER on
the FC60SS module
2 Audible Alarm sound
The ESI processor
has detected an
internal fault on one of
the following modules:
– PSU
– Cooling
– FC60SS
RAID
Replace faulty module as appropriate:
– PSU
– Cooling
– FC60SS RAID
Note See also Section 4.5.5.
Drive Fault On On
Power control circuit failure Off On
Table 4–6 Drive Carrier LED Functions
State Green Amber