User guide
Troubleshooting
47
Chapter 4
Troubleshooting and
Problem Solving
4.1 Overview
FC60SS enclosures include a processor and associated monitoring and control logic to
enable them to diagnose problems within the enclosure’s power, cooling and drive systems.
The sensors for power and cooling conditions are housed within the Power Supply modules. There is
independent monitoring for each unit.
If a fault is indicated on the Ops Panel, please refer to Table 4–3.
4.1.1 Initial Start-up Problems
4.1.1.1 Faulty Cords
First check that you have wired up the subsystem correctly. Then, if:
• cords are missing or damaged
• plugs are incorrect
• cords are too short
Call your supplier for a replacement.
4.1.1.2 Alarm Sounds On Power Up
Please refer to Section 4.3.
4.1.1.3 Green “Signal Good” LED on FC60SS RAID Module Not Lit
Check that the Rx and Tx cables have not been reversed during installation. Also check that the SFP is
properly seated and that the ends of optical cables are clean and undamaged. If the condition persists,
try replacing the SFP and/or cables.
4.1.1.4 Computer Doesn’t Recognize the FC60SS Enclosure
1 Check that the FC interface cables from the FC60SS enclosure to the host computer are fitted
correctly.