User guide

Table 3–3 Ops Panel LED States
Ops Panel LEDs Other Associated
LEDs or Alarms
State Description
Power
On
(Green/
Amber)
System
Fault
(Amber)
Logical
Fault
(Amber)
Box
Identify
(Blue)
On Off Off X Aux present, overall power failed or switched off.
On On On On single beep, two
double beep
Ops Panel power on (5s) test state
On Off X X Power On, all functions good
On On X X PSU Fault LED or
Cooling Module
Fault LED
Any PSU Fault or Fan Fault
Over or Under temperature
On On X X FC60SS RAID
Controller Fault
LED on lower
controller
ESI processor/ FC60SS RAID Controller 0 failed
On On X X FC60SS RAID
Controller Fault
LED on upper
controller
ESI processor/ FC60SS RAID controller 1 failed
On Flashing X X FC60SS RAID
Controller Fault
LED
Unknown (invalid or mixed) module type installed, or
12C Bus Failure (inter ESI processor).
On Flashing X X PSU Removed: PSU removed when two were present at Start of Day
On (X) Off X Power On, all functions good
On (X) On X Array in failed or
degraded state:
Drive failure has occurred causing loss of availability or
redundancy.
On (X) Flashing X Arrays in impacted
state:
Arrays performing background function
X X X On SES controlled enclosure identify.
Operation
43
Note: “X” = no bearing on these states