User guide
Operation
41
Chapter 3
Operation
3.1 Before You Begin
Before powering up the FC60SS enclosure please ensure that all the modules are firmly
seated in their correct bays.
3.2 Power On
Power on the enclosure by connecting cables to the PDU, or powering on the PDU, then power on the
Host system.
Caution Do not operate this equipment until the ambient temperature is within the specified operating range. If the
drives have been recently installed ensure they have had time to acclimatize before operating them.
Note Please refer to Section 3.5 for details of the Ops Panel LEDs and related fault conditions.
Follow the procedure below to Power On the enclosure.
1 Apply AC power to the enclosure.
2 The Power On LED on the Ops Panel should be lit (Green) when the enclosure power is activated (and
the disk drive motors should start).
Note The Power On LED on the Ops Panel should be lit Green at power up to indicate that the system is
functioning correctly, all other Ops Panel LEDs are off. If any LEDs show Amber then a problem exists
and the procedure in
Chapter 4 should be followed.
Important If AC power is lost for any reason, on restoration of power the enclosure will re-start
automatically.
3.3 Power Supply Module LEDs
The Power Supply module incorporates 2 LEDs.
• Under Normal conditions the Power On LED should be illuminated constant GREEN
• If a problem is detected the Module Fault LED will be illuminated constant AMBER.