User guide

Getting Started
37
Warning Some electrical circuits could be damaged if external signal cables or power control cables are
present during the grounding checks.
Check for continuity between the earth pin of the IEC 320 connector on one of the Power Supply
modules and any exposed metal surface of the FC60SS enclosure.
2.13 Embedded StorView Initial Setup
If this is the first startup of the Embedded StorView module, you will probably need to configure the
network settings.The Embedded StorView module supports both DHCP and manual network settings. By
default the Embedded StorView module will look for a DHCP server to obtain an IP address. If one is not
found, it will search to determine if an IP address had been previously assigned. If an address was not
previously assigned, then the system defaults to an IP address of:
10.1.1.5 for the lower RAID Controller (Controller 0)
10.1.1.6 for the upper RAID Controller (Controller 1)
10.1.1.7 if an error is detected
Subnet Mask is 255.0.0.0
A tool is provided to configure new Embedded StorView modules. From Windows platforms it is access
via the Embedded link on the disc navigation menu and on Linux it is accessed via a command line
executable.
When the Embedded StorView Setup program is run, it will broadcast UDP packets and any Embedded
StorView module will reply with UDP packets containing their information. A list of “uninitialized” systems
is displayed. Uninitialized systems are those which have not had the default user name and password
changed. Even if a configuration is created with arrays and logical drives but the login name and
password have not been changed, it will still be considered an uninitialized system During the process of
configuring an Embedded StorView module, you will be required to enter a “new’ password and confirm
that password. The default password is “password.”
The Embedded StorView module is identified by its MAC and IP address. It may be more helpful during
setup to configure one Embedded StorView module at a time.You will find the MAC address located on
a label affixed to the top of the controller case or by accessing the VT-100 text-based menu function for
Embedded StorView Menu mode and viewing the network settings. Note the specific address of each
controller in multiple controller environments and the location where that specific controller is installed in
the enclosure.
2.13.1 Setting up the Embedded StorView Module: Microsoft
Windows
1 Insert the Software and Manuals CD into your CD drive. the autorun program will automatically start the
navigation menu, click on the link for the hardware (FC60SS) product which you have installed.
2 Click the Embedded StorView Setup link to begin the Setup Wizard.
3 You are presented with a Welcome screen and instructions to proceed. Review the information and click
the Next button. (
Figure 2–18)