User guide

Introduction
17
1.5.8 Interfaces
Drive support See drive carrier specification
Attachment 1 domain of 12 drives per FC60SS RAID module
2 Fibre Channel Host Ports (Arbitrated Loop, Point-Point & Fabric attachment
supported)
2 x SFP optical per FC60SS RAID module
1 SAS Expansion Port
1 X SFF
1.5.9 FC60SS RAID Module Specification
Speed Host Ports: two 4Gb/sec Fibre Channel, also supporting 2Gb/sec and
1Gb/sec mode
Drive Ports: 3Gb/s SAS, creates connections to a single domain of 12
drives
Mounting Rear, horizontal in Bay 4 (see Figure 1–3)
Connectors 2 x SFP connectors for Host 0 and Host 1 Ports, to accommodate optical
interconnects (LC to LC cable), maximum length 500m
1 x 4xSAS Expansion connector (SFF)
1 x RJ45, 10/100BaseT Ethernet connection
1 x RS232 (factory use only)
Power Consumption 40W
LED Functions
LED Functions LED State Definition
Controller Slot 0 Activity* Amber When ON the Controller is currently processing data
Controller Slot 1 Activity* Amber When ON the Controller is currently processing data
Controller OK Green Module OK
Controller Fault Amber Fault on this module
Cache Active Amber Active cache contents
Battery/Controller Fail Amber Fault in battery or charger operation of controller
Host 0 Port Signal Good Green When ON the LED denotes that incoming FC signal is
good
Host 1 Port Signal Good Green When ON the LED denotes that incoming FC signal is
good
Host 0 Port Traffic* Amber When ON the Controller is processing data on this
port
Host 1 Port Traffic* Amber When ON the Controller is processing data on this
port