General requirements:-
Cord type Harmonized, H05-VVF-3G1.0
Socket IEC 320, C-13, 250V, 10A.
Important The Plug and the complete power cord assembly must meet the standards appropriate to the
country, and must have safety approvals acceptable in that country.
1.5.7 Environment
Table 1–5 Ambient Temperature and Humidity
Temperature Range Relative Humidity Max. Wet Bulb
Operational 5°C to 40°C 8% to 80%
non-condensing
23°C
Non-Operational 1°C to +50°C 8% to 80%
non-condensing
27°C
Storage 1°C to +60°C 8% to 80%
non-condensing
29°C
Shipping -40°C to +60°C 5% to 100%
non-precipitating
29°C
Airflow System must be operated with low pressure rear exhaust installation
(Back pressure created by rack doors and obstacles not to exceed 5
pascals [0.5mm Water gauge])
Altitude, Operational 0 to 3045 m (0 to 10,000ft)
Altitude, Non-Operational -305 to 12,192m (-1000 to 40,000ft)
Shock, Operational Vertical axis 5g peak 1/2 sine, 10ms
Shock, Non-Operational 30g 10ms 1/2 sine
Vibration, Operational 0.21grms 5-500 Hz Random
Vibration, Non-Operational 1.04grms 2-200 Hz Random
Vibration, Relocation 0.3g 2-200 Hz sine
Acoustics Sound Power Operating:
Less than 58 dB LwA measured at 23°C.
Sound Pressure Operating:
Less than 6.8 Bels LwA measured at 23°C.
Orientation & Mounting 19" Rack mount (2EIA Units)
Rack Rails To fit 800mm depth Racks compliant with IEC 297
Rack Characteristics Back pressure not exceeding 5 pascals (0.5mm water gauge)
Safety & Approvals CE, UL, cUL
•EMC EN55022 (CISPR - A), FCC A