User guide

Figure 1–17 Anti-tamper Lock
Enclosure User Guide
14
1.4.7 Dummy Carrier Modules
Dummy Carrier modules are provided for fitting in all unused drive bays. They are designed as integral
drive module front caps and must be fitted to all unused drive bays to maintain a balanced airflow.
1.4.8 Blank Modules
When only one FC60SS RAID module is installed, a Blank module must be fitted in the vacant RAID (I/O)
module slot at the rear of the enclosure to maintain airflow and ensure correct operation.
Warning Operation of the Enclosure with ANY modules missing will disrupt the airflow and the drives will
not receive sufficient cooling. It is ESSENTIAL that all apertures are filled before operating the FC60SS
enclosure system.
1.5 FC60SS Enclosure Technical
Specifications
1.5.1 Dimensions
Enclosure inches mm
Height 3.46 87.9
Width across mounting flange 19 483
Width across body of enclosure 17.6 447
Depth from flange to rear of enclosure body 21.65 550
Depth from flange to maximum extremity of enclosure
(rear hold down)
22.72 577
Depth from flange to furthest extremity at front of unit 1.44 36.5
It is recommended that a rack with a depth of no less than 700mm (27.55 inches) is used with this product.