Safety Data Sheet Page 2 of 7
Cutter Lemon Eucalyptus Insect Repellent
Revision date: 03/10/2017
Chemical Name
CAS#
Weight Percent
Oil of Lemon Eucalyptus
129828-24-6
30.00%
Ethanol
64-17-5
45.00%
Note: Ingredients not identified are proprietary or non-hazardous. Values are not product
specification(s).
Eye contact: Hold eye open and rinse slowly and gently with water for
15-20 minutes. Remove contact lenses, if present, after the
first 5 minutes, then continue rinsing. Call a poison control
center or doctor for treatment advice.
Skin contact: No special requirements
Inhalation: No special requirements
Ingestion: No special requirements
Notes to physician: None
General advice: If you feel unwell, seek medical advice (show the label
where possible). Ensure that medical personnel are aware
of the material(s) involved, and take precautions to protect
themselves. Keep out of reach of children.
Flammable properties: Flammable liquid category 3. Flashpoint 78
0
F.
Suitable extinguishing media: Water fog, alcohol resistant foam, CO
2
, dry chemical
Unsuitable extinguishing media: Not available
Specific hazards arising from the
chemical: Flammable liquid. Vapors are heavier than air and may
travel to a source of ignition and flash back. Liquid run-off
to sewers may create fire/explosion hazard. Container
may melt and leak in heat of fire. Do not allow run-off
from firefighting to enter drains or water courses.
Protective equipment for firefighters: Firefighters should wear full protective clothing including
self-contained breathing apparatus.
Hazardous combustion products: None known
Sensitivity to mechanical impact: None known
Explosion data: Not available
Sensitivity to static discharge: Not available
Personal precautions: Keep unnecessary personnel away. Do not touch or walk
through spilled material. Do not touch damaged containers
or spilled material unless wearing appropriate protective
clothing. Keep people away from and upwind of spill/leak.