Specific Code 39 Parameters.
This Section configures parameters associated with the Code 39 barcode type.
There are two types of Code 39, the Standard and Full ASCII versions. The standard
version encodes the numbers 0 thru 9, the upper case letters A thru Z and the characters:
space, -, ., *, $, /, + and %. The Full ASCII, or extended, version encodes all 128 ASCII
characters. The additional, or extended, characters are encoded as character pairs, result-
ing in a longer code.
The Start and Stop characters, which are the asterisk (*) character, can be transmitted
along with the other characters in the code.
Code 39 may be printed with a check digit. If so, this scanner has the options of calculating
the check and transmitting it as part of the data transmission. If the check digit calculation
fails, no transmission is made.