User manual
1.3.2 Setting serial interface
See paragraph 1.2.2.
1.3.3 Power-On confi guration
The JP8 jumper on controller board (see Fig.1.5) manages the power-on setting function as indicated:
J8
CLOSED Auto Power-On enabled
OPEN Auto Power-On disabled
If JP8 is closed: The printer switches on when powered up, and it switches off when power is off (default
condition). In this condition the ESC ‘0’ command has not effects.
If JP8 is open: When the printer is powered up the low-consumption mode is activated. An impulse of at
least 500 m/sec on pin 6 of the serial RS232 connector must be given to switch on the printer (see par.
2.2.1 and table 2.2). Use ESC “0” command to switch off the printer and bring it back to low-consumption
mode.
Refer to Fig. 1.5 for the JP8 jumper position.
JP8
JP5
JP6
JP7
JP4
RS232
TTL
JUMPER
SELECTION
POWER-ON
CLOSE=AUTO
OPEN=EXTERNAL
JUMPERS
SELECTION
INTERFACE
JP8
JUMPER
SELECTION
POWER-ON
CLOSE=AUTO
OPEN=EXTERNAL
•
•
(Fig.1.5)
1. INSTALLATION AND USE
User Manual PLUS II 1-5