Specifications

• In setting count-down mode, the maximum value of the counter is sa and the minimum
value is sb. If counting down reaches a value less than the minimum, it resets to the
maximum value. If the counter value set by sc is outside the counter operation range,
the counter value is forced to convert to the maximum value by executing $1D $63.
• Parameters sa to sc can be omitted. If omitted, they remain unchanged.
• Parameters sa to sc cannot contain characters other than ‘0’ to ‘9’.
[Default] sa = 1, sb = 65535, sn = 1, sr = 1, sc = 1
[Reference] $1D $43 $30, $1D $43 $31, $1D $43 $32, $1D $63
[Example]
$1D $48
Printers: KPM150
[Name] Select printing position of Human Readable Interpretation ( HRI ) characters
[Format] ASCII GS H n
Hex 1D 48 n
Decimal 29 72 n
[Range] 0 n 3, 48 n 51
[Description] Selects the printing position of HRI characters when printing bar codes. n selects the
printing positions as follows:
n FUNCTION
0, 48 Not printed
1, 49 Above the barcode.
2, 50 Below the barcode.
3, 51 Both above and below the barcode.
[Notes] HRI characters are printed using the font speci ed by $1D $66.
[Default] n = 0
[Reference] $1D $66, $1D $6B
[Example]
$1D $49
Printers: KPM150
[Name] Transmit printer ID
[Format] ASCII GS I n
Hex 1D 49 n
Decimal 29 73 n
[Range] 1 n 3, 49 n 51
[Description] Transmits the printer ID speci ed by n follows:
n PRINTER ID SPECIFICATION
1, 49 Printer model ID $41
2, 50 Type ID See table below
3, 51 ROM version ID Depends on ROM version (4 characters)
KPM54 Emulation
86 Command Reference