SDS
Conforms to OSHA HazCom 2012 Standard and WHMIS 2015
SAFETY DATA SHEET
Page 5 of 11
Polyblend® Ceramic Tile Caulk(Sanded)
Section 8: EXPOSURE CONTROLS/PERSONAL PROTECTION
8.1 CONTROL PARAMETER
Exposure Guidelines:
Occupational Exposure Limits
Chemical Name
OSHA-PEL
ACGIH-TLV
Calcium Carbonate
5 mg/m³ (Resp.)
15 mg/m³ (Total)
5 mg/m³ (Resp.)
Crystalline Silica, Quartz
0.025 mg/m³
0.025 mg/m³ (Resp.)
Titanium Dioxide
5 mg/m³ (Resp.)
15 mg/m³ (Total)
10 mg/m³ (Resp.)
Petroleum Hydrocarbon
10 mg/m
3
5 mg/m
3
Ammonium Hydroxide
50 ppm
25 ppm
8.2 EXPOSURE CONTROLS
Engineering Controls:
Use ventilation adequate to keep exposures (airborne levels of
dust, fume, vapor, etc.) below recommended exposure limits.
8.3 INDIVIDUAL PROTECTION MEASURES
8.3a. Personal Protective Equipment:
i. Eye/Face Protection: Wear approved eye/face protection [properly fitted dust- or splash-
proof chemical safety goggles/face (face shield)]
ii. Skin Protection:
1. Hand Protection: Wear impervious gloves, such as nitrile.
2. Body Protection: Wear suitable protective clothing
iii. Respiratory Protection: A NIOSH approved respirator or filtering face piece, such as N95,
is recommended in poorly ventilated areas or when permissible exposure limits may be
exceeded. Respirators should be selected by and used under the direction of a trained
health and safety professional following requirements found in OSHA’s respirator standard
(29 CFR 1910.134) and ANSI’s standard for respiratory protection (Z88.2).
iv. General Health and Safety Measures: Handle according to established industrial hygiene
and safety practices.
Section 9: PHYSICAL AND CHEMICAL PROPERTIES
Appearance (physical state, color, etc.):
Textured Paste(Various Colors)
Odor:
Acrylic
Odor Threshold:
Mild
pH:
7.0 – 9.0
Melting point/Freezing point:
Not Available
Initial boiling point and boiling range:
Not Available
Flash point:
>212°F(>100°C)