SDS

Conforms to OSHA HazCom 2012 Standard and WHMIS
SAFETY DATA SHEET
Occupational Exposure Limits
Chemical Name
OSHA-PEL
ACGIH-TLV
Sodium hydroxide
2 mg/m
3
2 mg/m
3
Ethylene glycol monobutyl ether
50 ppm
20 ppm
8.2 EXPOSURE CONTROLS
Engineering Controls:
Use ventilation adequate to keep exposures (airborne levels of
dust, fume, vapor, etc.) below recommended exposure limits.
8.3 INDIVIDUAL PROTECTION MEASURES
8.3a. Personal Protective Equipment:
i. Eye/Face Protection: Wear approved eye protection [properly fitted dust- or splash-proof
chemical safety goggles/face (face shield)]
ii. Skin Protection:
1. Hand Protection: Wear impervious gloves, such as nitrile.
2. Body Protection: Wear suitable protective clothing
iii. Respiratory Protection: A NIOSH approved dust mask or filtering face piece is
recommended in poorly ventilated areas or when permissible exposure limits may be
exceeded. Respirators should be selected by and used under the direction of a trained
health and safety professional following requirements found in OSHA’s respirator standard
(29 CFR 1910.134) and ANSI’s standard for respiratory protection (Z88.2).
iv. General Health and Safety Measures: Handle according to established industrial hygiene
and safety practices.
Section 9: PHYSICAL AND CHEMICAL PROPERTIES
Appearance (physical state, color, etc.):
Clear Liquid
Odor:
Characteristic
Odor Threshold:
Not available
pH:
13.1 – 13.7
Melting point/Freezing point:
Not available
Initial boiling point and boiling range:
>212°F(>100°C)
Flash point:
>200°F(>93.3°C)
Evaporation rate (Water=1):
Not available
Flammability:
Not flammable
Upper Flammability/Explosive Limit:
Not available
Lower Flammability/Explosive Limit:
Not available
Vapor Pressure
Not available
Vapor Density:
Not available
Relative Density:
0.99 – 1.05 g/mL
Solubility in Water:
Miscible
Partition coefficient: n-octanol/water:
Not available
Page 5 of 11