Specifications
Curtis PMC 1223/33, 1225/35, 1227/37 Manual
61
6 — PROGRAMMER OPERATION
Diagnostics and Special Diagnostics “Menu”
This is not a menu as such, but simply a list of the possible messages you may see
displayed when the programmer is operating in either of the Diagnostics modes.
The messages are listed in alphabetical order for easy reference.
BB WI R I NG CHECK
BB wiring check failed
EM BRAKE DRVR FAULT
Electromagnetic brake driver fault
HARDWARE FA I LSAFE 1
EEPROM fault
HARDWARE FA I LSAFE 2
Output section fault
HARDWARE FA I LSAFE 3
Main contactor fault
HARDWARE FA I LSAFE 4
Overcurrent fault
HPD
High pedal disable (HPD) activated
HW F A I L S A F E
Motor voltage fault
LOW BATTERY VOL TAGE
Battery voltage too low
a
NO KNOWN FAULTS
No known faults
OVERVOLTAGE
Battery voltage too high
b
PRECHARGE FAULT
Precharge fault
PROC /WI R I NG FAULT
HPD fault present >5 seconds
SRO
Static return to off (SRO) activated
THERMAL CUTBACK
Cutback, due to over/under temp
THROTTLE FAULT 1
Throttle fault
a
<16 volts (24V models); <21 volts (36V models); <27 volts (48V models)
b
>36 volts (24V models); >48 volts (36V models); >60 volts (48V models)