Specifications

Curtis PMC 1223/33, 1225/35, 1227/37 Manual
34
3 — PROGRAMMABLE PARAMETERS
DIRECTION [default access: OEM]
The direction input type denes how the controller decides when to
change direction. For wigwag throttles, the direction input type defaults to
respond to the throttle input. For single-ended throttles, this parameter can be
set to either single or dual. The single setting allows the direction to be
chosen via a single switch, which pulls the direction/reverse input (Pin 13) high
when reverse is selected. It is not necessary for the switch to connect Pin 13 to B-
when forward is selected. The dual setting requires input from two switches:
one for reverse (Pin 13) and one for forward (Pin 12). In the dual conguration
the switch must pull the forward or reverse input to B+ to select the direction.
Selecting both forward and reverse at the same time will cause the controller to
inhibit the output, disabling the vehicle until only one direction is selected.
These three optionsTypes 0 through 2 in the Direction programming
menuare listed in Table 5.
Table 5 PROGRAMMABLE DIRECTION INPUT TYPES
DIRECTION
APPLICABILITY
INPUT
Wigwag Single-Ended
TYPE Throttle Throttle DESCRIPTION
0 (responds to throttle input)
1 single allows direction to be
selected via a single switch
2 dual requires direction to be
selected via inputs from individual
forward and reverse switches