Specifications
Curtis PMC 1223/33, 1225/35, 1227/37 Manual
22
2 — INSTALLATION & WIRING:
Throttle
The speed limit pot also limits the vehicle’s reverse speed. Reverse speed is
linearly proportional to the speed limit pot setting and is adjustable from the
Mode 1 minimum speed (speed limit pot in its minimum speed position) to the
programmed maximum reverse speed (speed limit pot in its maximum speed
position).
If a speed limit pot is not used, the speed limit input (Pin 4) can be jumpered
to the pot high input, as shown in Figure 14. In this configuration, the vehicle
speed at full throttle is defined by the programmed maximum speed. If no
jumper is used, the vehicle speed at full throttle will be limited to the pro-
grammed minimum speed, which by default will also apply to reverse.
Fig. 14 Wiring of speed
limit input to enable
maximum speed when no
speed limit pot is used.
Pin 4
Pin 1
Speed Limit Pot Wiper
Pot High Input
PIN KEY
87654321
16 15 14 13 12 11 10 9
JUMPER
If a speed limit pot will never be used in the application, the controller can
be factory-configured without the speed limit feature (see Section 4), and the
jumper will not be required. With such a controller, the vehicle speed at full
throttle is defined by the programmed maximum speed, and it is possible to
program the reverse speed to a lower value if so desired.