Specifications

Curtis PMC 1223/33, 1225/35, 1227/37 Manual
16
2 — INSTALLATION & WIRING:
1227/37 Controllers
1227/37 Wiring Configurations
The 1227/37 controller can be congured to work with either on/off or momen-
tary switches for selecting direction and mode. If a power enable switch is used,
it must be momentary style. For more information on control switches, see p. 24.
With on/off switches
Typical wiring for the 1227/37 controller with on/off switches is presented in
Figure 9. This diagram shows the controller congured with the program 1 driver
as an electromagnetic brake, the program 2 driver as a brake light driver, and two
SPST switches used for selecting direction. NOTE: In the conguration shown, the
power enable pin is an output that drives the Status LED. With on/off switches,
Fig. 9 Basic wiring configuration using on/off switches, Curtis PMC 1227/37 controller.
M- A2
B+B-
BRAKE
REV
MULTI
MODE
HORN
SPEED
LIMIT
POT
(100k)
PUSH
5k
POT
THROTTLE
BELLY
BUTTON
feature available only on 1237 models
INHIBIT
FWD
16-pin detail:
FORWARD
POWER
ENABLE
MULTI
MODE
DIRECTION/
REVERSE
KSI
PROGRAM 2
DRIVER
PUSH
INHIBIT
MAIN
PROGRAM 1
DRIVER
SPEED
LIMIT
POT LO POT HI
POT
WIPER
HORN
BELLY
BUTTON
optional switch operated by mechanical brake release
CONTROL
FUSE
KEY
SWITCH
R
H
BRAKE
LIGHT
POWER
FUSE
A
MAIN
MAIN
B+
B-
Battery
Voltage
R
24V 1.5 k, 0.5 W
36V 2.4 k, 1 W
48V 3.2 k, 2 W
87654321
16 15 14 13 12 11 10 9
*
*