Specifications

Curtis PMC 1223/33, 1225/35, 1227/37 Manual
14
1227/37 CONTROLLERS
1227/37 Installation
The 1227/37 controller can be mounted in any position, but the location should
be carefully chosen to keep the controller clean and dry. If a clean, dry
mounting location cannot be found, a cover must be used to shield the
controller from water and contaminants.
The outline and mounting hole dimensions for the 1227/37 controllers are
shown in Figure 8. To ensure full rated output power, the controller should be
fastened to a clean, flat metal surface with three screws.
Although not usually necessary, a thermal joint compound can be used to
improve heat conduction from the case to the mounting surface.
Fig. 8 Mounting
dimensions, Curtis PMC
1227/37 controllers.
2 — INSTALLATION & WIRING:
1227/37 Controllers
66 (2.6)
28 (1.1)
122
(4.80)
152 (6.00)
6.3 (0.25)
22 (0.85)
65
(2.56)
4.8 (0.19)
21
×
16
×
1.5
(0.83
×
0.63
×
0.06);
8.4 (0.33) dia. hole thru
6.7 (0.265) dia.,
3 plcs
Dimensions in millimeters and (inches)
Status LED
C
L
165 (6.50)
127 (5.00)