Specifications
Curtis PMC 1223/33, 1225/35, 1227/37 Manual
13
With momentary switches
Typical wiring for the 1225/35 controller with momentary switches is
presented in Figure 7. This diagram shows the controller configured with the
program 1 driver as an electromagnetic brake, the program 2 driver as a brake
light driver, and a single direction switch. NOTE: When a momentary switch is
used for the mode input, the controller will always power up in Mode 1 (the
default mode).
2 — INSTALLATION & WIRING:
1225/35 Controllers
Fig. 7 Basic wiring configuration using momentary switches, Curtis PMC 1225/35 controller.
M2 M1
B-
B+
INHIBIT
BRAKE
DIRECTION
MULTI
MODE
HORN
SPEED
LIMIT
POT
(100kΩ)
POWER
ENABLE
5k
Ω POT
THROTTLE
BELLY
BUTTON
feature available only on 1235 models
PUSH
16-pin detail:
optional switch operated by mechanical brake release
FORWARD
POWER
ENABLE
MULTI
MODE
DIRECTION/
REVERSE
KSI
PROGRAM 2
DRIVER
PUSH
INHIBIT
BRAKE +
PROGRAM 1
DRIVER
SPEED
LIMIT
POT LO POT HI
POT
WIPER
HORN
BELLY
BUTTON
16 15 14 13 12 11 10 9
A
POWER
FUSE
R R R
H
BRAKE
LIGHT
B+
B-
CONTROL
FUSE
KEY
SWITCH
*
*
87654321
Battery
Voltage
R
24V 1.5 k
Ω
, 0.5 W
36V 2.4 k
Ω
, 1 W