1225/35 CONTROLLERS
1225/35 Installation
The outline and mounting hole dimensions for the 1225/35 controllers are
shown in Figure 5.
Fig. 5 Mounting
dimensions, Curtis PMC
1225/35 controllers.
2 — INSTALLATION & WIRING:
1225/35 Controllers
Dimensions in millimeters and (inches)
48
(1.88)
159 (6.25)
148 (5.83)
116
(4.58)
127
(5.0)
4.57 (0.180) dia.,
4 plcs
The 1225/35 controller can be oriented in any position. To ensure full rated
output power, the controller should be positioned so that the maximum available
airflow travels across its ribs. Fasten the controller to a secure mounting bracket
or other surface, using the four mounting holes provided. Be sure to allow easy
access to the controller’s connection face so that the 1307 handheld programmer
can be plugged into the controller after it is installed.
The 1225/35 case is designed to meet the IP54 seal requirements for
environmental protection against dust and water splash. However, it is neverthe-
less recommended that the controller be mounted in a clean and dry location.