Slowly move the sync control to the maximum. The display
should change to the sync mode and count up to 9o.
Disconnect and reconnect the red wire. The bulb should light brightly
with no delay, the display should read 10. Disconnect the red wire.
Test Manual Activation
With the output control still set at maximum, slowly activate the manual control slide button.
The bulb should start dim and get brighter and the display should
count up to 10 as the manual control is pushed.
While holding the manual control all the way in, slide the output control
up and down. As the output changes, the bulb should go bright and dim
and the display should read 0 to 10.
If the brake control unit does not function as described, return it for service or replacement.