Installation Guide

Installation GuideLightGrid Internal Node 2.x Series
2
Before Installation
Wiring the Node into a Fixture
Carefully unpack unit. Inspect for defects before installing.
Check Electrical parameters. Ensure that the xture operating wattage is below 1000W, and the voltage at
the xture is within the allowed range of the Controller. Using controller outside these parameters will void its
warranty.
Validate Fixture Approval with Current. Prior to integrating the Internal Node in any xture, Current strongly
recommends validation testing of the design to ensure LightGrid performance.
Following the Wiring Diagram, perform the following steps:
Connect the L-In (black) of the node to the line (black) of the xture.
Connect L-Out (Red) of the node to Line of the driver
Connect the neutral (white) of the node to the neutral (white) of the xture
Connect the neutral (white) of the LED Driver/HID Ballast to the neutral (white) of the xture
For dimmable xture, please perform the following
extra steps:
Connect the Dim- (grey) of the node to the negative
dimming wire of the LED Driver/HID Ballast.
Connect the Dim+ (violet) of the node to the
positive dimming wire of the LED Driver/HID Ballast.
Required Supplies.
LightGrid Internal Node
Luminaire
#10 mounting Screws of suitable type and length (recommended)
1
3
2
Wiring Diagram Incoming AC Power
Neutral Chassis
L-IN
N
L-OUT
Dim-
Dim+
ANT
COM
Chassis
Neutral
Line
Dim-
Dim+
Antenna
Unused
Lighting Fixture
LED Driver/
HID Ballast
Lightgrid
Node
Black
White
White
Black
Green
Green
Line
Red
Gray
Purple
Yellow
Brown
Black
WARNING
RISK OF DAMAGE ON NODE
Risk of damage on the node or xture if all
wiring instructions are not respected.
WIRING SET UP
All wiring setup should conform to NFPA70:
National Electrical code and CSA-22.