Specifications
3.13.2 Returning the Generator Set to Service
12-2008 3. Starting and Running the Generator Set
No. Description
1 Fuel Drain Bolt
FIGURE 16. CARBURETOR DRAIN
1. Add a fuel preservative and stabilizer to the fuel tank, or let the generator set run out of
fuel. Follow the manufacturer ’ s instructions for using the fuel additive.
2. Shut the fuel valve and drain the carburetor bowl. See the figure above.
3. Remove the spark plug. Squirt one tablespoon (about 1 ounce / 30 cm
3
) of clean engine oil
into the spark plug hole. Turn the engine over several revolutions. Replace the spark plug.
Pull the recoil starter handle out slowly until compression is felt.
4. Change engine oil and attach a tag indicating the viscosity of oil used.
5. Disconnect the cables from the starting battery, negative ( – ) cable first. Store the battery in
accordance with the battery manufacturer's recommendations.
6. Store the generator set in a dry, protected area.
1. Check the tag on generator set to verify that oil viscosity is correct for the current ambient
temperature. Add or change oil as necessary.
2. Reconnect the starting battery, neagative ( – ) cable last.
3. Clean the air cleaner if dirty.
4. Open the fuel valve.
5. Start the generator set. Initial start-up may be rough and smoky due to the extra oil in the
cylinder. Remove and clean the spark plug if necessary.
914-0103 (Issue 3) 27