General Generator Maintenance Intervals
Service Item Mthly 50 Hrs 100 Hrs 150 Hrs 200 Hrs 250 Hrs 450 Hrs 500 Hrs
Model Service Intervals - Repeat Every
CAMP POWER
/MICROLITE
/MICROQUIET
Clean & Check Battery & Connections X (3)
Clean Arrester X (5)
Change Oil X (1-4)
Change Air Filter X (2,4,5)
Replace Spark Plugs X (5)
Change Fuel Filter X (5)
Schedule Onan Service Center Tune-Up X (6)
EMERALD ADVANTAGE
/MARQUIS PLATINUM
/MARQUIS GOLD
Clean & Check Battery & Connections X (3)
Clean Spark Arrester X (5)
Change Oil/Oil Filter X (1-4)
Change Air Filter X (2)
Replace Spark Plugs X (5)
Change Fuel Filter X (5,6)
Schedule Onan Service Center Tune-Up X (6)
EMERALD
/MARQUIS
Clean & Check Battery & Connections X (3)
Clean Spark Arrester X (5)
Change Oil/Oil Filter X (2-4,7)
Change Air Filter X (2,4,5)
Replace Spark Plugs X (4,5)
Change Fuel Filter X (5)
Schedule Onan Service Center Tune-Up X (6)
DIESEL
Clean & Check Battery & Connections X (3)
Clean Spark Arrester X (5)
Change Oil/Oil Filter – All Except Quiet Diesel
X (1-4) X (2-4)
Change Oil/Oil Filter – Quiet Diesel 5500 X (1-4) X (2-4)
Change Oil/Oil Filter – Quiet Diesel 7500/8000 X (1-4) X (2-4)
Change Oil/Oil Filter – Quiet Diesel 10000/12500 X (1-4) X (2-4)
Change Air Filter X (2,5)
Change Fuel Filter – All Except Quiet Diesel X (5)
Change Fuel Filter – Quiet Diesel X (5)
Schedule Onan Service Center Tune-Up* X (5,6)
1 As a part of engine break-in, change the engine oil after the first 20-50 hours of operation.
2 Perform more often when operating in dusty environments.
3 Perform more often when operating in hot weather.
4 Perform at least once a year.
5 Perform sooner if engine performance deteriorates.
6 Must be performed by a qualified mechanic (Onan Authorized RV Service and Parts Dealer).
7 As a part of engine break-in, change the engine oil after the first 50 hours of operation.
* Injector check and clean or replace.
Series Spec Letter Operators Parts Service Installation
MicroQuiet KY A 981-0139 981-0246B 981-0503 981-0627
KY B-C 981-0139 981-0246B 981-0503 981-0607
KY D-H 981-0154 981-0246B 981-0503 981-0607
KY J 981-0159C 981-0246B 981-0530 981-0621
KY K 981-0159C 981-0246C 981-0530 981-0621
KY L 981-0159C 981-0246D 981-0530 981-0621
KY Tracker E-F 981-0155 981-0246B 981-0503 981-0611
Quiet Diesel 10000 HDCAA A-B 981-0152C 981-0259C 981-0526D 981-0615C
Quiet Diesel 10000 HDCAA C 981-0170 981-0259D 981-0526D 981-0637
Quiet Diesel 12500 HDCAB A-B 981-0152C 981-0259C 981-0526D 981-0615C
Quiet Diesel 12500 HDCAB C 981-0170 981-0259D 981-0526D 981-0637
Quiet Diesel 7500 HDKAJ A-H 981-0161 981-0200D 981-0522B 981-0623
Quiet Diesel 8000 HDKAK A-H 981-0161 981-0200D 981-0522B 981-0623
Quiet Diesel 5500 HDKBA A 981-0166B 981-0271 981-0535 981-0633B
Quiet Diesel 5500 HDKBA A-C 981-0166B 981-0271B 981-0535 981-0633B
Quiet Diesel 10000 HDKCA Kubota A 981-0173 981-0277 981-0540 981-0640
Quiet Diesel 12500 HDKCB Kubota A 981-0173 981-0277 981-0540 981-0640
Marquis Platinum HGJAA A-C 983-0101B 983-0201C 983-0501C 983-0600
Marquis Gold HGJAB A-C 983-0101B 983-0201C 983-0501C 983-0600
Emerald Advantage HGJAC A-C 983-0101B 983-0201C 983-0501C 983-0600
MicroLite KV A-B 981-0129 981-0238F 981-0506 981-0626
KV C-D 981-0136 981-0238F 981-0518D 981-0604
KV E-K 981-0153C 981-0238F 981-0518D 981-0604
KVC A-C 981-0158C 981-0238F 981-0518D 981-0620
Camp Power KVD A 981-0164B 981-0238F 981-0518D 981-0631B
KYD A-B 981-0169 981-0246D 981-0530 981-0636
RV Generator Manuals