Troubleshooting guide
55
54
RV Inverter:
• Maintains full load output at high ambient temperatures
• 3-stage, temperature compensated battery charging and equalization for all battery
types
• Low battery shut-off provides longer battery life
• Automatic generator start with programmable ‘quiet time’ helps maintain optimum
battery levels and can start the generator on thermostat request for AC; included at
no extra cost
• Battery charge rate ‘power share adjust’ gives appliances priority to reduce AC
breaker trips
• AC and battery terminal blocks for easy installation and secure connections
• FCC Class B radiated EMI performance
• Automatically assumes load when AC power from generator or shore is not available
• Shunt option calculates battery state of charge and usage time remaining
• UL Listed to U.S. and Canadian Safety Standards
Remote Panel:
• Easy-to-use, full text, customer-friendly readout
• Easy-to-interpret diagnostics and fault history on remote panel
• LED lights provide inverter status at a glance
• ’Quick-key‘ for easy charge rate adjustments
• Full AC and DC metering
METERING
AC INPUT
FAU LT
CHARGING
CHARGED
AUTO GEN
INVERTERCHARGER
INVERT
ON/OFF
CHARGE
BATT
BATTERY
Model 1500 kW 2000 kW 2500 kW 3000 kW
INVERTER FUNCTION
Max Continuous Output Power AC 1500 2000 2500 3000
Peak Current (Surge rated peak 300%) 37 50 62 75
CHARGER FUNCTION
Max Charge Output DC Amps 75 A dc 100 A dc 120 A dc 140 A dc
Charge Control 3-Stage 3-Stage 3-Stage 3-Stage
Equalization S S S S
Battery Type Settings wet/gel/agm wet/gel/agm wet/gel/agm wet/gel/agm
Temperature Compensated Charging S S S S
TRANSFER SWITCH
AC Transfer Switch Amps 30 30 30 30
SPECIFICATIONS
Two Speed Forced Air Cooling S S S S
Specified Temperature Range -20° C to +40° C
Enclosure Type Metal
Dimensions (L x W x H) 12.2" x 12.8" x 7.3"
Weight (lbs) 45 47 50 51
Recommended Class T DC Fuse 200 A 300 A 300 A 400 A
Remote Control Panel O O O O
30A Pass Thru S S S S
20/20 Breakers O O O O
15/15 Breakers O O O O
Internal Shunt
(for battery level monitoring) O O S S
Auto Generator Start/Stop S S S S
Auto LowBatt Cutout S S S S
Power Sharing S S S S
Fault Diagnosis S S S S
Battery Voltage 12 V DC 12 V DC 12 V DC 12 V DC
AC Input Voltage 120 V AC 120 V AC 120 V AC 120 V AC
AC Output Connections Terminal Block
AC Input Connections Terminal Block
Onan Equinox Inverter - Size Comparison Chart
S=Standard, O=Optional