Troubleshooting guide

55
54
RV Inverter:
Maintains full load output at high ambient temperatures
3-stage, temperature compensated battery charging and equalization for all battery
types
Low battery shut-off provides longer battery life
Automatic generator start with programmable ‘quiet time’ helps maintain optimum
battery levels and can start the generator on thermostat request for AC; included at
no extra cost
Battery charge rate ‘power share adjust’ gives appliances priority to reduce AC
breaker trips
AC and battery terminal blocks for easy installation and secure connections
FCC Class B radiated EMI performance
Automatically assumes load when AC power from generator or shore is not available
Shunt option calculates battery state of charge and usage time remaining
UL Listed to U.S. and Canadian Safety Standards
Remote Panel:
Easy-to-use, full text, customer-friendly readout
Easy-to-interpret diagnostics and fault history on remote panel
LED lights provide inverter status at a glance
’Quick-key‘ for easy charge rate adjustments
Full AC and DC metering
METERING
AC INPUT
FAU LT
CHARGING
CHARGED
AUTO GEN
INVERTERCHARGER
INVERT
ON/OFF
CHARGE
BATT
BATTERY
Model 1500 kW 2000 kW 2500 kW 3000 kW
INVERTER FUNCTION
Max Continuous Output Power AC 1500 2000 2500 3000
Peak Current (Surge rated peak 300%) 37 50 62 75
CHARGER FUNCTION
Max Charge Output DC Amps 75 A dc 100 A dc 120 A dc 140 A dc
Charge Control 3-Stage 3-Stage 3-Stage 3-Stage
Equalization S S S S
Battery Type Settings wet/gel/agm wet/gel/agm wet/gel/agm wet/gel/agm
Temperature Compensated Charging S S S S
TRANSFER SWITCH
AC Transfer Switch Amps 30 30 30 30
SPECIFICATIONS
Two Speed Forced Air Cooling S S S S
Specified Temperature Range -20° C to +40° C
Enclosure Type Metal
Dimensions (L x W x H) 12.2" x 12.8" x 7.3"
Weight (lbs) 45 47 50 51
Recommended Class T DC Fuse 200 A 300 A 300 A 400 A
Remote Control Panel O O O O
30A Pass Thru S S S S
20/20 Breakers O O O O
15/15 Breakers O O O O
Internal Shunt
(for battery level monitoring) O O S S
Auto Generator Start/Stop S S S S
Auto LowBatt Cutout S S S S
Power Sharing S S S S
Fault Diagnosis S S S S
Battery Voltage 12 V DC 12 V DC 12 V DC 12 V DC
AC Input Voltage 120 V AC 120 V AC 120 V AC 120 V AC
AC Output Connections Terminal Block
AC Input Connections Terminal Block
Onan Equinox Inverter - Size Comparison Chart
S=Standard, O=Optional