Troubleshooting guide

43
42
MicroLite and MicroQuiet Specifications
*Typical RV installation. All readings at 10 ft. (3m).
Dimensions: (L x W x H in inches)
2800 & 2500 LP: 24.0 x 16.4 x 12.3
4000 & 3600 LP: 30.0 x 19.7 x 14.4
Engine Detail:
4-cycle, single cylinder, overhead valve.
Power Capabilities: (at 100ºF and 500' altitude)
• MicroLite 2800: Starts one 13500 BTU air conditioner with approved start
circuit, plus 600-watt baseload. Or, one 11000 BTU air conditioner with
approved start circuit, plus 1000-watt baseload.
• MicroLite 2500 LP: Starts one 13500 BTU air conditioner with approved start
circuit, plus 300-watt baseload. Or, one 11000 BTU air conditioner with
approved start circuit, plus 600-watt baseload.
• MicroQuiet 4000: Starts one 13500 BTU air conditioner, plus
2000-watt baseload.
• MicroQuiet 3600 LP: Starts one 13500 BTU air conditioner, plus
1600-watt baseload.
Model 2800 2500 LP 4000 3600 LP
Watts 2800 2500 4000 3600
RPM 3600 3600 3600 3600
Volts 120 120 120 120
Hertz 60 60 60 60
Amps 23.0 20.8 33.3 30.0
Weight (lb) 113 113 172 172
Avg. Fuel
Consumption (gal/hr) (gal/hr) (lb/hr) (gal/hr) (gal/hr) (lb/hr)
No Load 0.2 0.2 0.9 0.3 0.4 1.7
Half Load 0.3 0.3 1.3 0.5 0.6 2.6
Full Load 0.4 0.5 2.1 0.7 0.7 3.0
Sound Level dB(A)
Half Load* 70 70 66 66
Engine Horsepower 7 7 9.5 8.6
LIGHTWEIGHT, COMPACT AND QUIET
GASOLINE/LP RV GENERATORS
MicroLite
• Runs one 13500 BTU air conditioner with power to spare and
easy-start motor circuit.
• Lightweight and compact.
• Single-side service for easy maintenance.
• Fully-enclosed muffler.
• Gasoline or LP-fueled.
MicroQuiet
Includes all the features and benefits above, PLUS…
• Microprocessor control with diagnostics for easy troubleshooting.
MICROLITE
2800
MICROQUIET