Specifications
2. Introduction 9-2010
Full Load 275,000 Btu/Hr 240,000 Btu/Hr 229,000 Btu/Hr 213,000 Btu/Hr
110 ft
3
/Hr 240 ft
3
/Hr 90 ft
3
/Hr 205 ft
3
/Hr
Fuel Pressure 7-11 inches WC 5-11 inches WC 7-11 inches WC 5-11 inches WC
Tank Size Contact your local gas company to verify the tank size required for your application.
TABLE 5. ENGINE SPECIFICATIONS TABLE
60 Hz 50 Hz
Propane Vapor Natural Gas Propane Vapor Natural Gas
Engine 2 Cylinder-V Twin, OHV, Air-Cooled, 4-Stroke, Spark Ignited, 3600 RPM
Displacement 60.59 in
3
(993 cc)
Spark Plug Gap .020 inch (.51 mm)
Spark Plug Torque 15 ft-lb (20 N-m)
Intake and Exhaust Cold Valve 0.004-0.006 inch (0.10 - 0.15 mm)
Lash
(Measure at 0.25" (6.35mm)
past top dead center)
Oil Capacity Approximately 80 oz (2.3 Liters)
Oil Recommendation 0W-40 Synthetic Engine Oil
(See Operator Manual)
TABLE 6. GENERATOR SPECIFICATIONS TABLE
60 Hz 50 Hz
Propane Vapor Natural Gas Propane Vapor Natural Gas
Generator Brush-Type, 2-Pole Rotating Field, Single Bearing
Power (kVA) --- --- 13.5 13.5
Rated Voltage (V) 120/240 120/240 115/230 115/230
Rated Current (Amps) 162.6/81.3 143.6/71.8 117.4/58.7 117.4/58.7
Phase Type Single Phase
Circuit Breaker (Amps) 100 100 60 60
De-rating Guidelines: Maximum wattage or maximum current are subject to and limited by such factors as fuel Btu
content, ambient temperature, altitude, engine power and condition, etc. Full rated power is available at 60 °F (15.5
°C) at sea level. De-rate 3.5% for each 1000 ft (304.8 m) above sea level and 3% for each 10 °F (5.5 °C) increase in
ambient temperature above 60 °F (15.5 °C).This generator is rated in accordance with UL 2200 (Stationary Engine
Generator Assemblies) or CSA C22.2 No. 100-04 (Motors and Generators). The maximum continuous current values
that are listed on the generator set nameplate and specification tables occur at the lower limit of acceptable voltage.
Maximum current occurs at 108 and 216 volts, 10% below nominal voltage 120/240. The voltage set point of this
generator set can be adjusted from the operator panel if desired. Refer to the Operator manual procedure To Adjust
the Output Voltage.
TABLE 7. CONTROL SPECIFICATIONS TABLE
60 Hz 50 Hz
Propane Vapor Natural Gas Propane Vapor Natural Gas
Controller Integrated Microprocessor-Based Engine, Generator, Transfer Switch Controller
8 A029V089 (Issue 3)