Product Card

Open Enclosed
Dimensions
Air
Standby Rating Prime Rating
Combustion air, m
3
/min
4.60 4.30
Maximum air cleaner restriction, kPa 6.2
Exhaust
Exhaust gas flow at set rated load, m
3
/min
4.9 4.5
Exhaust gas temperature,
°
C
509 493
Maximum exhaust back pressure, kPa 6.7
Standard set-mounted radiator coolin
g
Ambient design,
°
C
55
Fan load, KW
m
2 +/- 1
Coolant capacity (with radiator), L 15
Cooling system air flow, m3/sec @ 12.7mmH2O 1.9
Total heat rejection, BTU/min 5543 4993
Width Height
Maximum cooling air flow static restriction mmH2O 12.7
Weights
*
Unit dry weight kgs 1005 1455
2600 1115 1795
Unit wet weight kgs 1165 1585
* Weights represent a set with standard features. See outline drawing for weights of other configurations
Length
Genset outlin
e
Open set
Enclosed set
Outlines are for illustrative purposes only. Please refer to the genset outline drawing for an exact representation of this model.
Standard open set dimensions 2115 1044 1516
Enclosed set standard dimensions
©2011 | Cummins Power Generation Inc. | All rights reserved | Specifications subject to change without notice | Cummins Power Generation and Cummins are registered trademarks of Cummins Inc.
PowerCommand and “Our energy working for you.” are trademarks of Cummins Power Generation. Other company, product, or service names may be trademarks or service marks of others.
Document no. DS376-CPGK-RevA - 25/1/2012