Specification Sheet

Cummins
®
, Onan
®
, the "C" logo, Performance you rely on.
TM
and Standard Diesel
TM
are
servicemarks, trademarks and/or registered trademarks of Cummins Inc.
Racor
®
is a registered trademark of Parker Hannifin Corp.
Specifications are subject to change without notice
©2011 Cummins Power Generation. All Rights Reserved.
A-1390g (4/11)
Standard features
Engine details
3-cylinder diesel engine
Brush type AC alternator
Focalized mounting system with 4-point vibration
isolators
Cross-flow radiator
Full flow lube oil filter
Fuel filter/water separator
Vertically mounted fuel and oil filters
Replaceable element air cleaner
Remote mountable DC control box
4-position exhaust elbow
30 A battery charging DC alternator
Lifting bracket
Glow plugs for easy starting
Base pan for drip control
Electric fuel pump
Top and side oil fill and check for platform or
compartment installations
Model: Kubota D1105
Design: 4-cycle, liquid-cooled diesel engine
Cylinders: 3, inline vertical
Bore: 3.07 in (78.0 mm)
Stroke: 3.09 in (78.4 mm)
Displacement: 68.53 in
3
(1124 cm
3
)
Compression ratio: 24:1
Lube oil capacity: 5.39 qt (5.1 L)
Power (max): At 1800 r/min: 17.1 hp
Cooling system capacity: 1.25 Gal (4.73 L)
Starting system: Remote, 12 V, 1.2 kW starter
Fuel injection pump: Bosch K mini
Fuel pump: Electric
Combustion chamber: Spherical
Typical fuel consumption
No. 2 diesel fuel, Gal/hr (L/hr)
No load
Half load Full load
7.5HDKAL
0.25 (0.95) 0.56 (1.93) 0.9 (3.41)
6.0HDKAL
0.23 (0.87) 0.46 (1.74) 0.8 (3.03)
Alternator details
Design: Cummins Onan, brush type, drip proof
construction
Insulation system: Class F, per NEMA MGI-1.65
and BS 2757; insulating varnish conforms to MIL-I-
24092, grade CB, Class 155 C
Three-phase models: Broad range reconnectable
design for installed voltage flexibility
Exciter system: Electronic voltage regulation
Bearing: Double sealed, pre-lubricated ball bearing
Cooling:
Direct drive centrifugal blower
Damper bar system:
Generator set design
incorporates a damper bar system for low harmonic
waveform distortion. This design feature becomes
significant when powering SCR type loads (converters,
etc.)
Generator set details
Control
- Unit mounted, drip-proof, vibration isolated console
DC controls, 12 V system
- Start/stop/preheat switch
- Remote connector for start/stop/preheat switch and
gauge package
- Manual reset fault relay indicating engine shutdown for
high coolant temperature, low oil pressure
- Hour meter
AC controls
- Electronic voltage regulator
- Three-phase models, factory shipped reconnectable
(no breaker)
- Three-phase breaker kits available for field fitted
installation
No load/full load Constant load
Voltage regulation:
±2.5% ±1%
Frequency regulation:
±2.5% ±1%