Specification Sheet
Performance you rely on.
TM
  cumminsonan.com 
©2015 Cummins Power Generation Inc. | A-1441k (8/15) 
Specification sheet 
Commercial 
generator set 
Quiet Gasoline
TM
Series QG 7000 
Features and benefits 
 Integrated hydraulic pump option (pictured) 
 Quietest and lowest vibration generator set in 
its class 
 Integrated housing design 
 Enclosed muffler for ease of installation 
 Self-diagnostic capability to simplify 
troubleshooting 
 Runs two ACs with power to spare 
 Digital regulation for voltage stability as loads 
change 
 2-year limited warranty, 5-year drive warranty 
Weight, size and sound level 
Weight: 
299 lbs (136 kg) 
Size:
  Length 33.6 in (853 mm), width 22.2 in 
(563 mm), height 16.7 in (425 mm) 
Sound: 
70 dB(A) at 10 ft (3 m), typical installation, 
full load 
Models and ratings 
Model Fuel Packaging Hz Watts Voltage Amps PF Phase 
Circuit 
breaker 
7 HGJAE-2132 (3243**) 
Gasoline  Tubbed  60  7000  120  58.3  1.0  1  2 pole, 30 A 
7 HGJAE-2556# 
Gasoline  Crated  60  7000  120/240  29.2  1.0  1  2 pole, 30 A 
7 HGJAE-1912 (2023**) 
Gasoline  Tubbed  60  7000  120/240  29.2  1.0  1  2 pole, 30 A 
7 HGJAE-6758 (7869**) 
Gasoline  Tubbed  60  7000  120/240  29.2  1.0  1  2 pole, 30 A 
7 HGJAE-2137 
Gasoline  Crated  60  7000  120/240  16.8  1.0  3  3 pole, 18 A 
6.5 HGJAE-2145 (3256**) 
LP vapor  Tubbed  60  6500  120/240  27.1  1.0  1  2 pole, 30 A 
6.5 HGJAE-3554 (4665**) 
LP vapor  Tubbed  60  6500  120  54.0  1.0  1  2 pole, 30 A 
- All 60 Hz models operate at 2880 r/min. 
- Ratings apply up to 3000 ft (914 m) altitude, 85° F (29.4° C). 
- Derating: Power output will decrease 3.5% for each 1000 ft (305 m) above 3000 ft (914 m), temperature derate not 
required for ambient** temperatures under 120° F (49.2° C). Temperature: Power output decreases 1% for every 10 °F 
(5.5 °C) increase. 
- Ratings are at intermittent power output. 
# 
Splined shaft. 
* Ambient is defined as the air temperature measured at the cooling air inlet to the set. 
**Factory OEM packaging 
 Evaporative spec: For trailer applications required to meet Tier III Evaporative emissions of the California Air Resources 
board. 
 Effective January 1, 2011, gasoline generator sets on trailers, diesel chassis or any other non-motorized mobile 
apparatus must have an EVAP generator set, approved tank, EVAP canister, hoses and fittings all meeting the CARB 
Tier 3 and EPA phase 3 standards and specifications. This law applies in all 50 states. 
 Generator weight does not include battery charger or splined shaft. 