Product Manual B

5. Maintenance 3-2018
70 A051X877 (Issue 7)Copyright © 2018 Cummins Inc.
Maintenance Items
After Every
24 Hours
of Run
Time
1
After Every
50 Hours
of Run
Time
12 Months or
After 250
Hours
2
2 Years or
After 500
Hours
2
Check battery for general
condition. Remove any
corrosion on terminals with wire
brush.
Check electrical connections
(battery, starter motor, alternator
connections). Check for tight
connections, general condition
and remove any corrosion.
Replace engine oil and filters.
Refer to the Engine Oil section
for the procedure.
4
4
Check engine ground. Clean as
necessary.
Check engine mounts for
general condition and for signs
of excessive wear.
Check starting motor.
Check turbocharger for signs of
leakage. Listen for excessive
noise when test running the
generator set.
Inspect spark plugs. Replace if
showing signs of excessive
wear, carbon deposits, oil
accumulation or damaged.
Replace spark plugs and spark
plug wires.
Check charge air cooler for
damage and debris.
Check valve lash and adjust if
required. See the Valve
Clearance Adjustment
procedure (service manual
only).
Check fan drive idler arm and
fan belt tensioner for general
condition, as well as for
excessive play in both.