Product Manual B
3. Control System 3-2018
34 A051X877 (Issue 7)Copyright © 2018 Cummins Inc.
• Press Save to save any changes. After saving, the Save button changes to the
Adjust button.
FIGURE 6. EXERCISE DURATION NAVIGATION
Time Setup (3-Phase ATS)
NOTICE
When battery power is lost, these settings must be reset.
NOTICE
Not applicable without an RA series transfer switch.
To set up the generator set clock for the current date and time:
1. From any Information Menu, hold down the up and down arrows simultaneously
for two seconds. The Service Menu appears.
2. Access the Time Setup screen by selecting Clock Exerciser on the Genset
Service Menu.
3. Select Adjust.
When updating these settings, the functions of the keys are as follows:
• The horizontal right arrow key is used to select successive blocks for editing
settings on the screen.
• Select the left arrow to return to the previous screen.
• Adjust values by using the + or - keys on the Adjust Menu of the Time Setup
screen.
• Press Save to save any changes. After saving, the Save button changes to the
Adjust button.