5. Maintenance7-2018
73A045R242 (Issue 12) Copyright © 2018 Cummins Inc.
Maintenance Item
Daily
or After
24 Hours
Weekly
or After
50 Hours
100
Hours
1 Year
or After
200 Hours
1
2
Years
1
4000
Hours
Check water pump
for leaks. Check
weep holes for
evidence of leaks.
Replace if leaking.
■
Check engine
ground. Clean as
necessary.
■
Check engine
mounts general
condition and for
signs of excessive
wear.
■
Check starting
motor for general
condition, wiring
connections.
■
Check
turbocharger
(where fitted) for
signs of leakage.
Listen for
excessive noise
when test running
the generator set.
■
Check timing belt
condition. Visually
inspect.
■
Inspect spark
plugs. Replace if
showing signs of
excessive wear,
carbon deposits,
oil accumulation or
damaged.
■
Check battery
condition.
■