Product Manual B

5. Maintenance 7-2018
72 A045R242 (Issue 12)Copyright © 2018 Cummins Inc.
Maintenance Item
Daily
or After
24 Hours
Weekly
or After
50 Hours
100
Hours
1 Year
or After
200 Hours
1
2
Years
1
4000
Hours
Check generator
set enclosure:
Visually check
enclosure, walk
around inspection
of generator set.
Make sure no
inlets/outlets are
covered/restricted,
service access
doors are
operational and
safety systems are
in place and
operational.
Check operation of
Emergency Stop
Button (where
fitted): With the
generator set
running, press the
Emergency Stop
button. Check all
systems, before
resetting the fault.
Replace engine oil
and filters. Refer
to the procedure in
the Engine Oil
section.
2
2
Check battery:
Check connections
to verify that they
are secure.
Replace air
cleaner.
Clean radiator
core.
3
Check charge air
cooler for damage
and debris (where
fitted).