Electrical Schematic
CKD
FIRST USED ON
FOR INTERPRETATION
OF DIMENSIONING AND
TOLERANCING, SEE
APVD
DWN
SIM TO
UNLESS OTHERWISE SPECIFIED, ALL
DIMENSIONS ARE IN MILLIMETERS
17.50-24.99 +0.30/-0.13
10.00-17.49 +0.25/-0.13
5.00- 9.99 +0.20/-0.10
0.00- 4.99 +0.15/-0.08
DIM
HOLE
ANG TOL
DO NOT SCALE PRINT
SCALE
SITE CODE
CUMMINS POWER GENERATION
SIZE
DWG
D
DATE
A053F522
6
5
4
3
2
1
D
C
B
A
6
5
4
3
2
1
D
C
B
A
PTC Creo Parametric
R
R
THIS DOCUMENT (AND THE INFORMATION SHOWN THEREON) IS
CONFIDENTIAL AND PROPRIETARY AND SHALL NOT BE DISCLOSED TO OTHERS
IN HARD COPY OR ELECTRONIC FORM, REPRODUCED BY ANY MEANS, OR
USED FOR ANY PURPOSE WITHOUT WRITTEN CONSENT OF CUMMINS INC.
R
OF
CAD SHEET
1 4
NO
REV
REL NO
DATE
APVD
CKD
DWN
REVISION
CUSTOMER CONNECTIONS
TERMINAL
NAME
SIGNAL NAME DESCRIPTION
TB1 LOAD CONTROL 1 HIGH SIDE DRIVER, DESIGN VOLTAGE: 14VDC NOMINAL CURRENT:1A
TB2 LOAD CONTROL 2 HIGH SIDE DRIVER, DESIGN VOLTAGE: 14VDC NOMINAL CURRENT:1A
TB3 LOAD CONTROL 3 HIGH SIDE DRIVER, DESIGN VOLTAGE: 14VDC NOMINAL CURRENT:1A
TB4 LOAD CONTROL 4 HIGH SIDE DRIVER, DESIGN VOLTAGE: 14VDC NOMINAL CURRENT:1A
TB5 ATS CONTROL HIGH SIDE DRIVER, DESIGN VOLTAGE: 14VDC,NOMINAL CURRENT:1A
TB6 REMOTE START INPUT
DIGITAL INPUT(SWITCH TO GROUND), DESIGN VOLTAGE: 14VDC,NOMINAL CURRENT:1A
TB7 CUSTOMER GROUND GROUND, (1A MAX)
TB8 B+ 12VDC, 1A PROTECTED
TB9 ALARM OUTPUT LOW SIDE DRIVER, NOMINAL CURRENT:0.1A
1
X #
0.8
.X #
0.38
.XX#
1.0 1/1 ARROW
ASME Y14.5-2009
24AUG15
M_TULADHAR
M_TULADHAR
J_KHARJUL
DIAGRAM,WIRING
ECO-166256 E 1 ADD NOTE 3 PT MT
M_TULADHAR
28NOV16
2
ZONE (A4), ADD BATTERY DIAGRAM TO STARTER
PT MT
M_TULADHAR
28NOV16
3
ZONE (B6) ADD 'ETHERNET J3' TO DISPLAY
PT MT
M_TULADHAR
28NOV16
4 SEE SHEET 2 PT MT
M_TULADHAR
28NOV16
PGF
.
NOTES:
1. ALL DEVICES ARE SHOWN DE-ENERGIZED WITH TRANSFER
SWITCH CLOSED TO UTILITY.
2 SINGLE PHASE TRUE TWO POSITION MECHANISM. MAXIMUM
VOLTAGE UPTO 240 VAC.
3 SEE SHEET 2 FOR EMERGENCY STOP KIT CONNECTION (ZONE A1).
ALTERNATOR
FIELD-
FIELD+
QUAD+
QUAD-
TO (SEE SHEET 2)
OIL
LEVEL
SWITCH
W-16
HMI211A-RS
DISPLAY ASSY
PART NUMBER
A052D408
W-53
W-59
EQUIPMENT
GROUND
120/240 VAC
60/75 C WIRE
#4-#2 AWG
AL/CU
TORQUE TO
45 lb-in (5 Nm)
WINDING
RECTIFIER
FUSE 20A
BATTERY
FLYWHEEL BATTERY CHARGING COIL RECTIFIER CIRCUIT
+
-
TO ATS TB4-3
(SEE SHEET 3 OR 4)
TO ATS TB4-1
(SEE SHEET 3 OR 4)
t
NORMALLY CLOSED
CIRCUIT OPENS AT
91.5-98.5$C
(196.7-209.3$F)
CUSTOMER LOAD CONNECTION
NORMALLY CLOSED
SWITCH OPENS
AT 4.5-10.5 psi
STARTER B+2
NORMALLY
CLOSED
BATTERY
-
+
2
PE-2
PE-1
JE-1
JE-2
SP3
1
2
SP2
1
2
DISPLAY J2
FOR REMOTE DISPLAY
8
5
7
6
4
1
2
3
SP4
1
2
SP5
1
2
A049F902
P1
5
6
LOW OIL PRESSURE
7
LOAD CONTROL3
11
14
19
23
GOV ACTUATOR
26
27
30
32
33
OVERTEMP
9
8
16
STOP
ENG GND1
P1
13
1
2
3
34
35
17
15
18
LOAD CONTROL 1
24
CT 1+
CT COM1
CT2 +
CT2 COM
CURRENT SENSE-
SERVICE-J5
SERVICE CONNECTOR
FOR AUTHORIZED PERSONNEL ONLY
1
2
3
4
5
6
ENG GND2
P2
1
2
3
ATS CONTROL
4
REMOTE START INPUT
5
LOW OIL LEVEL
6
7
LOAD CONTROL 4
8
LOAD CONTROL2
BATT SW
STARTER
STARTER B+1
ACT POS
1
W-22
ACT NEG
FUEL
ACTUATOR
1
FSOL1+
FSGND1
OIL
PRESSURE
SWITCH
1
2
DISPLAY B+
TB2
1
2
TB1
1
2
TB4
1
2
TB7
3
2
1
4
5
TB5
1
2
TB6
1
2
B-
B+ INPUT
FUEL SOL+
CURRENT SENSE2+
U
W
114
115
NEUTRAL
1
1
B+ INPUT
AC-P
1
2
3
4
AC-J
1
2
3
4
CURRENT SENSE1+
QUAD1
(L1) (L2) N
DISPLAY J1
1
2
3
4
5
6
7
8
SP1
1
2
QUAD2
GEN VOLT SENSE S1
GEN VOLT SENSE S2
FIELD -
FIELD +
REMOTE ENABLE
TB-3
1
2
TB9
1
2
ALARM OUTPUT
FSOL2+
FSGND2
SP6
1
2
FUEL SOLENOIDS
SP7
1
2
1
SP8
1
2
SP9
1
2
TB8
3
2
1
4
5
TEMP
SWITCH
RS485-A
RS485-B
DISPLAY WAKEUP
25
E-STOP
3
3
ETHERNET J3
GENSET HARNESS
W-01
W-38
STARTER
W-41
W-26
W-10
W-42
W-45
W-46
W-06
W-27
W-18
W-19
W-23
W-17
W-15
W-39
W-37
W-40
W-28
W-36
W-30
W-31
W-32
W-33
W-34
W-35
W-03
W-20
W-44
W-43
W-65
W-51
W-49
W-56
W-24
W-25
W-08
W-11
W-09W-12
W-07
W-05
W-57
W-58
W-52
W-54
W-55
W-14
W-73
W-71
W-72
SAAC
HARNESS LEGEND
GENSET CONTROL
CARD PART NUMBER
A026E165
ECO-166256 Sheet 1 of 5
Part Name: A053F522 Revision: E
Drawing Name: A053F523 Revision: E