Product Manual
Table Of Contents
15
1-2019
Copyright © 2019 Cummins Inc.
A062R852 (Issue 1)
MANUAL START
Be sure to check oil levels before starting. If it is the rst
time starting make sure to add oil (see Initial Oil Fill on page
13).
1. Make sure nothing is plugged into any of the outlets.
2. Make sure battery is connected (see Hooking Up the
Battery on page 7).
3. Make sure the circuit breakers are properly set (see
Figure 6).
4. Turn the Fuel Control Switch to the ON position (see
Figure 7).
5. Turn the Engine Control Switch ON.
6. Firmly grasp and pull the recoil handle slowly until you
feel increased resistance. At this point, apply a rapid
pull while pulling out from the inverter (see Figure 9).
Figure 9: Pull the Recoil Handle out from Inverter
7. Once engine stabilizes. Plug in electronic devices.
DANGER
To prevent unintentional starting with
remote key fob the engine switch must be
OFF if the generator is inside or is outside
and not intended to be used for remote
start.
WIRELESS REMOTE START
1. Check oil levels.
2. Conrm Engine Control Switch is ON.
4. Conrm that the Fuel Control Switch is in the ON
position (see Figure 7).
5. Push and hold the START button on the wireless
remote until the inverter starts.
Note: the generator will try 3 times to make a successful
start.
ELECTRIC START
Be sure to check oil levels before starting. If it is the rst
time starting make sure to add oil (see Initial Oil Fill on
page 13).
1. Make sure nothing is plugged into any of the
outlets.
2. Make sure battery is connected (see Hooking Up
the Battery on page 7).
3. Make sure the circuit breakers are properly set
(see Figure 6).
1
2
Figure 6: Breakers
(1) 120V Circuit Breaker Operating Position
(2) 120V Circuit Breaker Tripped Position
4. Turn the Fuel Control Switch to the ON position
(see Figure 7).
Figure 7: Turn Fuel Switch to ON Position
5. Turn the Engine Control Switch ON.
6. Push and hold the engine start push button for 1
second and release (see Figure 8). The engine will
automatically set the choke and begin the start
sequence.
Figure 8: Electric Start Button - PUSH
Note: If the engine fails to start after 5 seconds, release the button.
Let the inverter sit idle for 15 seconds and then repeat step 6. If the
cranking speed drops after each unsuccessful attempt, then the
battery may not be adequately charged.
7. Once engine stabilizes. Plug in electronic devices.
OPERATION