Standard features
Engine details
Electronic fuel Injection (EFI) for clean, smooth
running under all conditions
Electronic governor
Cummins Onan OHV engine
Pressurized thru flow cooling system
4-point mounting system with coil spring vibration
isolators
Universal mounting tray with structural capability to
support the generator set in commercial mobile
applications
Integral USDA Forest Service-approved spark-
arrestor muffler
Integral control box
Instant one-touch stop switch
Electronic ignition
Self diagnostic capability
Hour meter
Battery charging - 5 A
Remote disable/continuous stop
Start and run without AC output - engine run only
Enclosed muffler provides noise reduction and ease
of installation
Sound-attenuated housing
Waterproof remote connector
Heavy-duty solenoid shift starter
Long-life fuel filter
Spin-on, full-flow oil filter
Low oil pressure protection
Over/under speed protection
Low power factor field over current protection
Digital voltage regulation
Hydraulic pump standard on some models
10 ft generator set output leads
Typical fuel consumption
Model: Cummins Onan OHV EH65V gasoline engine
Design: 4-cycle, OHV, 90-degree V-twin
Cylinders: 2
Bore: 80 mm
Stroke: 65 mm
Displacement: 39.8 in
3
(653 cm
3
)
Compression ratio: 8:1
Oil capacity: 2.0 qt (1.9 L) including filter
Power (max): At 2400 r/min: 11.6 hp
Cooling: Centrifugal blower, generator set mounted for
high effectiveness, pressurized system, vertical flow
Cooling air volume: 60 Hz: 500 ft
3
/min (14.2 m
3
/min) at
2400 r/min. Air flow includes engine, generator set and
control cooling air flow
Fuel system:
- Replaceable dry element air cleaner
- Gasoline side-draft throttle body.
- Remote mount electronic fuel pump with positive fuel
shutoff (45 psi), maximum fuel lift 3 ft (0.9 m)
- Combustion air volume: 60 Hz: 17.2 ft
3
/min (0.53
m
3
/min) at 2400 r/min
Starting system: Remote, 12 V, negative ground;
automotive type starter with steel pinion and ring gear,
automatic start disconnect, connector for remote start
cable, start-stop rocker switch mounted on set control
Ignition system: Electronic magneto type with
resistor plugs
Lubrication: Full pressure positive displacement lube
oil pump, spin-on, full flow lube oil filter, low oil pressure
shutdown, dipstick
Cylinder crankcase: Alloy aluminum with iron
cylinder liners cast into the block, aluminum oil base
Cylinder head: Aluminum, OHV, removable
Gasoline, Gal/hr (L/hr)
No load
Half load
5.5 HGJAD
Full load
0.35 (1.3)
)
0.60 (2.3)
0.95 (3.6)
Alternator details
Design: Cummins Onan, revolving field, AC, 2-pole
self-excited, two bearing design
Insulation system and temperature rise:
Meets requirements of NEMA MG-1 and CSA C22.2,
Std. 100 Motors and Generators
Cooling: Direct drive centrifugal blower, cast
aluminum housing for excellent heat transfer
Rotor: Laminated electrical steel assembly press-fitted
to shaft, balanced; heavy insulated copper wire
windings; optimized air gap for improved waveform and
motor starting; Class 200 magnet wire
Stator: Laminated electrical steel assembly, skewed
for improved waveform; Class 200 quadrature wire with
70% more insulation over comparable generator sets
Excitation: Capped, digital voltage regulation
DC brushes: Electrographic; long life
Bearing: Double-sealed pre-lubricated ball bearings
Generator set details
Hydraulic pump
- Fixed displacement gear pump, 1.5 Gal/min at 2500 psi
- A generator set with a hydraulic pump is rated with the
pump idle
- When using a non-Cummins Onan pump supplied by
the customer, the hydraulic pump shaft seals must be
capable of operating in a temperature environment of
225° F to 250° F. Seal failure will result in equipment
damage
2.0%
No load/Full load
1.7%
Voltage regulation:
Constant load
1.7%
Frequency regulation:
1.7%