Standard features
Engine details
Microprocessor control with digital voltage regulator
Starter overcrank protection
Generator set field overload protection
Over/under frequency and voltage protection
Loss of AC sense protection
Mechanical fault protection
Detects starter faults
Reverse connections and high battery voltage
protection
4-point vibration isolator mounting system
Magnetic circuit breaker
Automatic resetting of DC circuit overcurrent protection
for set wiring and remote start wiring
Integral enclosure cover and stamped steel base
Stationary exhaust pipe attachment point
High stability mechanical governor
Sealed remote start connector
Fuel filter
USDA Forest Service-approved, spark-arresting
muffler
Cross-flow pressure cooling
Automatic choke
Electric fuel pump with positive fuel safety shutoff
(gasoline)
Electric fuel shutoff solenoid (LPG)
125 in (3.2 m) generator set output leads
Intake silencer, sound deadening material and baffles
reduce sound level
Start-stop/prime rocker switch on control with LED
status indicator light for set diagnostics
Model: Cummins Onan E095H
Design: 4-cycle, OHV, single horizontal cylinder
Displacement: 18.5 in
3
(304 cm
3
)
Compression ratio: 8.5:1
Maximum power at 60 Hz:
LPG - 8.6 bhp (6.4 kW); Gasoline: - 9.5 bhp (7 kW)
Maximum power at 50 Hz:
LPG - 7.6 bhp (5.7 kW); Gasoline - 8.3 bhp (6.2 kW)
Cooling: Cross flow air - pressure type
Cooling air volume: Includes engine cooling air
volume
60 Hz: 300 ft
3
/min (8.5 m
3
/min)
50 Hz: 250 ft
3
/min (7.1 m
3
/min)
Combustion air volume:
60 Hz: 19 ft
3
/min (0.5 m
3
/min)
50 Hz: 16 ft
3
/min (0.45 m
3
/min)
Side draft carburetor: KY (gasoline)
Electric fuel pump: Positive fuel shutoff (3 psi), fuel
lift 3 ft (914 mm)
Air cleaner: Replaceable dry element; patented
automatic choke
Vapor withdrawal system with demand
regulator: KY (LPG)
Ignition system: Electronic magneto type
Starting system: Remote, 12 V, 3-wire negative
ground
Starter: Automotive type with environmentally
protected pinion; automatic start disconnect
Lubrication: Splash lubrication
Oil capacity: 1.6 qt (1.5 L)
Cylinder crankcase: Aluminum alloy with iron
cylinder liner cast into the block, aluminum alloy oil base
Cylinder head: Aluminum, valves in head, removable
Average fuel consumption:
Gasoline No load Half load Full load
60 Hz 4.0 KY
0.3 Gal/h (1.1 L/h) 0.5 Gal/h (1.8 L/h) 0.7 Gal/h (2.7 L/h)
50 Hz 3.6 KY
0.2 Gal/h (0.8 L/h) 0.4 Gal/h (1.4 L/h) 0.6 Gal/h (2.2 L/h)
LPG No load Half load Full load
60 Hz 3.6 KY
0.4 Gal/h (1.5 lb/h) 0.7 kg/h 0.6 Gal/h (2.4 lb/h) 1.1 kg/h 0.7 Gal/h (3.1 lb/h) 1.4 kg/h
50 Hz 3.3 KY
0.3 Gal/h (1.1 lb/h) 0.5 kg/h
0.5 Gal/h (2.2 lb/h) 1.0 kg/h 0.7 Gal/h (2.9 lb/h) 1.3 kg/h
Alternator details
Design: Cummins Onan revolving field, AC, 2-pole
self-excited; permanently aligned to engine by a tapered
shaft; drip-proof construction
Insulation system and temperature rise: Meets
ANSI/RVIA-EGS-1-1998, BS-4999 and CSA Electrical
Bulletin 946 standards
Cooling: Direct drive centrifugal blower, cast aluminum
housing for excellent heat transfer
Voltage regulation: Microprocessor control with
digital voltage regulator
Rotor: Laminated electrical steel assembly press fitted
to shaft, balanced; heavy insulated copper wire windings;
amortisseur windings for improved waveform and motor
starting
Stator: Laminated electrical steel assembly; heavy
insulated copper wire windings
DC brushes: Electrographite; long life
Bearing: Double-sealed, pre-lubricated ball bearing
Generator set performance
Air conditioner starting: (60 Hz - gasoline) one
13500 Btu air conditioner with 2000 W base load at
500 ft (152.4 m) and 100° F (38° C)
Frequency and voltage regulation: Exceeds
requirements of ANSI/RVIA EGS-1-1998