Spec Sheet
©2011 Cummins Power Generation. All Rights Reserved. Cummins
®
, Onan
®
, the “C” logo, Performance you rely on.
TM
and Quiet Gasoline™ are servicemarks and/or
registered trademarks of Cummins Inc. Specifications are subject to change without notice.
A-1399m (2/11)
RV generator set
Quiet Gasoline
TM
Series
RV QG 4000
Features and benefits
Weight, size and sound level
• Microprocessor control with diagnostics.
• Exceptionally smooth, quiet operation.
• Sealed connectors.
• Full housing with enclosed muffler.
• 3-year limited warranty.
• Lightweight, compact.
• OHV engine for efficiency, no decarboning.
Weight
172 lbs (83.4 kg)
Length
30.0 in (762 mm)
Width
19.7 in (500.4 mm)
Height
14.4 in (353.1 mm)
Sound
68 dB(A)
Readings at 10 ft (3 m) half load
- Meets National Park Service sound level requirements (60 dB(A)
@ 50 ft) for use in national parks.
- Typical installation will further reduce sound level.
Models and ratings
Model Fuel Hz RPM Watts Voltage Amps Phase Circuit breaker
4KYFR65697
Gasoline 60 3600 4000 100 (1) 40.0 1 20 A, 2-pole
4KYFA26100
Gasoline 60 3600 4000 120 33.3 1 30 A, 1-pole
4KYFA6747*
Gasoline 60 3600 4000 120 33.3 1 30 A, 1-pole
4KYFR11429
Gasoline 60 3600 4000 100 (2) 40.0 1 20 A, 2-pole
3.6KYFA26120
LP 60 3600 3600 120 30.0 1 30 A, 1-pole
3.3KYFR4858
LP 50 3000 3300 230 (2,4) 14.3 1 17 A, 1-pole
3.6KYFR4856
Gasoline 50 3000 3600 230 (2,4) 15.7 1 17 A,1-pole
(1) Isolated neutral, (2) Grounded neutral, (3) Adjustable 220-240, (4) Australia/New Zealand wire colors.
Ambient conditions for rated power output with muffler and RV enclosure, per ISO 8528-1:
- Temperature: 77° F (25° C)
- Altitude: 500 ft (152.4 m), (99 kPa dry)
Typical power output change based on ambient conditions:
- Temperature: Power output decreases 1% for every 10° F (5.5° C) increase
- Altitude: Power output decreases 3.5% for every 1000 ft (305 m) increase
Ratings represent minimums. Actual performance may be significantly higher based on installation and operating conditions.
* Evaporative spec: Effective January 1, 2011, gasoline generator sets on trailers, diesel chassis or any other non-motorized mobile apparatus
must have an EVAP generator set, approved tank, EVAP canister, hoses and fittings all meeting the CARB Tier 3 and EPA phase 3 standards
and specifications. This law applies in all 50 states.
Operating temperature range
Low High
Gasoline
-20° F (-29° C) 120° F (49° C)
LP
0° F (-18° C) 120° F (49° C)
- Depends upon LP tank capacity, surface area and butane content of LPG.